Omron NT21 - SETUP MANUAL 10-2001 Setup Manual page 45

Programmable terminal
Hide thumbs Also See for NT21 - SETUP MANUAL 10-2001:
Table of Contents

Advertisement

Using a Memory Unit
Reference:
Writing Screen Data to a
Memory Unit Using
Automatic Transmission
(PT to Memory Unit)
Reference: When screen data is written to the Memory Unit, the data that has been stored in
1, 2, 3...
ON
1
2
3
SW1
SW1-4 ON: System program
OFF: Screen data
Reference:
Pin
SW2 4
SW2-4
System/Screen simultaneous transmission
System/Screen simultaneous transmission
* The Memory Unit stores system program or screen data for one PT in each of
Areas (bank 0, bank 1). (The total data storage is for two PTs.) SW2-3 sets which
of these two banks is used for automatic transmission.
S In the following cases, a mode setting error occurs.
• More than one of the SW1-1 to SW1-3 switches are set to ON.
• None of the SW1-1 to SW1-3 switches are set to ON.
S In the following case, a protect setting error occurs.
Transmitting to the write destination has been disabled by the setting for
SW2-1 or SW2-2.
S In the following cases, a data transmission error occurs.
• An attempt is made to transmit data other than the system program to PT
System Program Area.
• An attempt is made to transmit the system program to PT Screen Data
Area.
S For details on mode setting errors and protect setting errors, refer to Errors
When Using a Memory Unit (page 36).
In this mode, system program or the screen data in the NT21 is forcibly written to
the Memory Unit irrespective of the setting status of the NT21.
This mode is convenient if the touch panel is broken and touch switch operation
is not possible, or if someone unfamiliar with touch switch operation at the opera-
tion site is using the system.
the specified Area up until that point is lost (if the data is written into only one
Bank, the other Bank will not be affected).
Method of Execution
Use the following procedure to write the system program or screen data in the
NT21 to the Memory Unit by automatic transmission.
1. Check that the power supply to the NT21 is OFF, then set the DIP switches of
the Memory Unit as follows after installing Memory Unit to NT21.
ON
4
1
2
3
SW2
SW2-3 ON: Bank 1
It is not strictly necessary to set SW2-1 to OFF (to disable writing to the PT),
but it is recommended to do so to avoid loss of data in the event of operating
errors.
S Setting SW2-4 to ON (System/Screen transmitted simultaneously) disables
the setting of SW1-4.
S Setting SW2-4 to ON (System/Screen transmitted simultaneously) disables
the setting of SW2-3, writes the system program into bank 0, and the screen
data into bank 1 at all times.
Function
4
SW2-4 ON: System/Screen transmitted simultaneously
OFF: System/Screen not transmitted simultaneously
OFF: Bank 0
Section
3-5
OFF: Disable
ON : Enable
33

Advertisement

Table of Contents
loading

Table of Contents