Starting The Pt; Operation At Startup - Omron NS - REV 12 Setup Manual

Ns-series programmable terminals
Table of Contents

Advertisement

3-2 Starting the PT

When a Bar Code Reader and the NT-AL001 are connected to ports
A and B at the same time
When the CJ1W-CIF11 and C1W-CIF11 are connected to ports A
and B at the same time
When the CJ1W-CIF11 and NS-AL002 are connected to ports A and
B at the same time
When the CJ1W-CIF11 and NT-AL001 are connected to ports A and
B at the same time
When two NT-AL001s are connected to ports A and B at the same
time
When a Bar Code Reader is connected to port A or B
When the CJ1W-CIF11 is connected to port A or B
When the NS-AL002 is connected to port A or B
When the NT-AL001 is connected to port A or B
When Bar Code Readers are connected to ports A and B at the
same time
When the NT-AL001 and NT-AL002 are connected to port A or B at
the same time

3-2 Starting the PT

Check that the hardware is connected properly, turn ON the power to the PT, and then start
the PT.
Use the following procedure to start the PT.
3-2-1

Operation at Startup

When the power is ON or the PT is reset, the PT will operate as follows:
Indicator lights orange.
Indicator lights green.
Startup message is displayed.
3-8
Port A and B connection combinations
Immediately after the power is turned ON, the indicator will light orange.
The file system will be checked and the system recovered if the power was turned OFF
while a file was being written in previous operation, or if the battery capacity was low and
drive safety information from the system program area screen data area could not be saved.
When the system starts properly, the indicator will light green.
If the indicator does not light green, the system programs may be damaged. Contact your
nearest OMRON representative.
A message about the startup status will be displayed.
If an error occurs, the PT will stop startup procedures and display a message. (Refer to Sec-
tion 5 Troubleshooting in the Programming Manual.)
If an error occurs that allows startup to continue, a warning will be displayed. When a warn-
ing is displayed, the PT will enter standby state and wait for touch input. Check the message
and then touch the screen. The PT will continue with startup procedures.
Expansion Interface Unit
(NS-CA001, NS-CA002,
NS-CLK21)
Cannot be used
Can be used
Can be used
Cannot be used
Cannot be used
Can be used
Can be used
Can be used
Can be used
Cannot be used
Cannot be used