System Program Version
The system program version installed in the PT must be version 6.2 or higher. Update to ver-
sion 6.2 or higher if the current version is 6.1 or lower.
USB Driver for PTs
To transfer screens using USB communications, a USB driver for the PT must be installed in
the computer. For details on installing the USB drivers, refer to 2-4 Installing USB Drivers for
NS-series PTs in the CX-Designer User's Manual.
PT Hardware Restrictions
NS-V1 PTs with lot number 0325 (manufactured February 3, 2005) or later support USB data
transfers. A commercially available USB cable can be used.
The manufacturing date can be checked using the 4-digit lot number given on the back of the
PT.
Lot No.
0 3 2 5 Manufactured February 3, 2005
Use a USB cable that is 2 m or shorter. If a distance of longer than 2 m is required for a USB
connection, use a commercially available USB Hub.
Up to 2 m
2 m max.
NS-V1 Series PT
Personal
computer
Longer than 2 m
2 m max.
NS-V1 Series PT
Recommended USB Hubs
USB-HUB203 (USB 2.0-compatible standard 4-port hub)
Commercially available and recommended USB Hubs do not have the same
Precautions
for Safe Use
specifications as the NS-series PT. Normal operation may not be possible in
environments subject to noise or static electricity. When using USB Hubs, be
sure to provide sufficient measures to prevent noise and static electricity, or
install in a location that is not subject to noise or static electricity.
Rightmost digit of the year, e.g.,
2005 in this example
Month: 1 to 9 = January to
September, X to Z = October to
December, e.g., February in this
example
Day of month, e.g., the 3rd in
this example