Installing Rs-232C/Rs-422A Converters; Mounting The Pt To The Control Panel - Omron NS - REV 12 Setup Manual

Ns-series programmable terminals
Table of Contents

Advertisement

3-1 Installing the PT
3-1-2

Installing RS-232C/RS-422A Converters

When using RS-232C/RS-422A Converters, mount the PT to the control panel before install-
ing these Units.
For details on installing and removing RS-232C/RS-422A Converters, refer to Appendix 3 Us-
ing NS-AL002 Converters.
3-1-3

Mounting the PT to the Control Panel

The PT is flush-mounted to the control panel.
The PT is mounted using the panel mounting brackets provided with the PT, and tools, such
as a Phillips screwdriver.
Use the following procedure to mount the PT to the control panel.
1. Make a hole in the panel for flush mounting according to the following dimensions and in-
sert the PT from the front of the panel.
Model
NS15
NS12
NS10
NS8
NS5
Reference
3-4
Height
Width
Dimensions
+1
Width 383.5
+1
Width 302
0
+1
Width 302
0
+0.5
Width 220.5
+0.5
Width 184
0
A NS-USBEXT-1M USB Relay Cable can be used to place a USB slave connector on
the front of the control panel. To use a USB Relay Cable, mount the Cable connector in
a panel cutout with the following dimensions.
20.8±0.1 dia.
Unit: mm
19.4±0.1 dia.
Recommended panel thickness:
1.6 to 4.8 mm
× Height 282.5
+1
mm
0
0
× Height 228
+1
mm
0
× Height 228
+1
mm
0
× Height 165.5
+0.5
mm
0
0
× Height 131
+0.5
mm
0

Hide quick links: