Installation notes

3-1
Installation notes
3-1-1
Location
3-1-2
Temperature control
3-1-3
Accessibility
3-1-4
Panel cut-out
8
For improved reliability and maximized functionality, take the following
information into consideration when installing a NQ-Series HMI.
Do not install the NQ-Series in the following locations:
Areas subject to explosion hazards due to flammable gasses, vapours and
dusts.
Areas subject to dramatic temperature changes. Temperature changes can
cause condensation of water in the device.
Areas with an ambient temperature lower than 0 °C or higher than 50 °C.
Areas subject to shock or vibration.
Provide adequate space for air flow.
Do not install the NQ-Series above equipment that generates significant
heat.
If the ambient temperature exceeds 50 °C, install a cooling fan or air
conditioner.
For safety during operation and maintenance, mount the NQ-Series as far
as possible from high-voltage equipment and power machinery.
Before the NQ-Series can be mounted, a rectangular cut-out must be made in
the panel in which the NQ-Series will be mounted. Table 3.1: Dimensions of
NQ-Series and required panel cut-out shows the dimensions and tolerances of
the NQ-Series, the panel and the required cut-out.
/i
Table 3.1: Dimensions of NQ-Series and required panel cut-out
Display size
External dimensions:
Panel cut-out:
Panel cut-out tolerance
Panel thickness
Above external dimensions and cut-outs are for landscape models.
For portrait models exchange the W and H sizes. For portrait models the
cables will be mounted to the left side of the NQ-Series (view from front).
NQ5-
5.7 "
W
195 mm
ext
H
142 mm
ext
W
184.00 mm
cut-out
H
131.00 mm
cut-out
+0.50 mm
Max. 6.0 mm
Section 3-1
NQ3-
3.5 " and 3.8 "
128 mm
102 mm
119.00 mm
93.00 mm
+0.50 mm
Max. 6.0 mm