Omron NQ HMI Getting Started Manual page 39

Nq-series hmi
Table of Contents

Advertisement

Using NQ-Designer
Register
Tag name
S0010
RTC day
S0011
RTC month
S0012
RTC year
S0013
RTC hour
S0014
RTC min
S0015
RTC sec
S0016
RTC day of the week
S0017
Scan time register
S0018
Communication recover
time[s] for port1
S0020
Driver scan time register
for port1
S0023
Popup screen trigger
register
S0116
Fact_Appln_1
S0117
Fact_Appln_2
S0118
Fact_Appln_3
S0119
Fact_Appln_4
S0120
Fact_Appln_5
S0121
Contrast control
(Retentive register)
S0122
Brightness control
(Retentive register)
S0123
Fact_Appln_6
S0124
Fact_Appln_7
S0125
Fact_Appln_8
/i
Table 4.4: Default system tags (Bit)
Register
Tag name
S0003_00 Logger memory full status Read
S0003_01 Logger memory clear
status
Read/Write
Description
Read
RTC day in integer format
Read
RTC month in integer format
Read
RTC year in integer format
Read
RTC hour in integer format
Read
RTC minute in integer format
Read
RTC second in integer format
Read
RTC day of week in integer
format
Read
Shows time required to
execute screen, screen task
and global task in millisecond.
Use ####.## format for
display.
Read/Write
Shows time in seconds to
recover the communication
with failed nodes for port1. The
default value is 60 sec.
Read
Shows time required to
execute screen blocks in
milliseconds. Use ####.##
format for display.
Read/Write
Holds the screen number for
the pop-screen that will be
shown when bit s20 bit is set.
Read/Write
Reserved
Read/Write
Reserved
Read/Write
Reserved
Read/Write
Reserved
Read/Write
Reserved
Read/Write
This retentive register used for
setting the contrast of the NQ-
Series.
Read/Write
This retentive register used for
setting the brightness of the
NQ-Series.
Read/Write
Reserved
Read/Write
Reserved
Read/Write
Reserved
Read/Write
Description
1: full memory
Read
1: memory clear is
being executed
Section 4-2
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nq3-tq0**bNq3-mq0**bNq5-sq0**bNq5-mq0**b