Changing Pulse-output Operation
Settings
Example: Changing the pulse width from 30 s to 20 s
1. Enter operation time setting mode
using
Key. The pulse width
MODE
is displayed.
2. Change the pulse width to 20 s
using
m/ WD
Key.
P
3. Press the
Key. The ON time
WRITE
for program 1 will be displayed.
(Make changes, if necessary, using
the
,
and
m/ WD
h
P
Key.)
4. Press the
Key to enter oper-
MODE
ation date setting mode. The opera-
tion dates will be displayed. (Make
changes, if necessary, using the
and
Keys.)
d
WRITE
5. Press the
Key. The Time
MODE
Switch will enter run mode and
operation will start.
Note: Operation based on the changed settings will start as soon as
the Time Switch returns to run mode.
The color indicates flashing
SU MO TU WE TH FR SA
30
P
PW
SU MO TU WE TH FR SA
20
P
PW
SU MO TU WE TH FR SA
7 40
AM
WRITE
P
PW
SU MO TU WE TH FR SA
P
PW
SU MO TU WE TH FR SA
7 30
AM
P
7 40
AM
PW
Clearing the ON/OFF Settings for
Individual Programs
Example: Clearing the settings for program 2
1. Enter operation time setting mode
using
MODE
program 1 will be displayed.
s
P
2. Press the
WRITE
ON time for program 2 will be dis-
played.
s
P
3. Press the
CLR
and OFF settings are cleared with
just one operation. If this operation
is performed while output is ON,
output stays ON until the Time
1
P
Switch returns to run mode.)
4. Press the
MODE
Time Switch will enter run mode
and operation based on the new
settings (i.e. without the cleared
P
programs) will start.
Note: Settings for pulse-output operation can be cleared for individ-
ual programs in the same way.

Clearing all Settings

1. Enter operation time setting mode
or operation date setting mode
using the
MODE
2. Press the
The clearing process will be com-
pleted 3 s has elapsed. Output will
turn OFF immediately.
3. When all the settings have been
cleared, the operation time, opera-
tion day, pulse width, holiday, partial
operation on specified day, and
override and automatic return oper-
ation settings will be returned to
their factory settings.
Note: The clearing process will be canceled if the
leased while clr is still flashing and only the settings for the
display program will be cleared.
Digital Daily Time Switch
Key. The ON time for
Key twice. The
Key. (Both the ON
Key twice. The
Key.
Key for 3 s min.
CLR
The color indicates flashing
SU MO TU WE TH FR SA
8 30
S
AM
ON
1
P
PW
SU MO TU WE TH FR SA
1 15
PM
ON
2
P
PW
SU MO TU WE TH FR SA
-- --
ON
2
P
PW
SU MO TU WE TH FR SA
10 30
AM
ON
0 30
PW
PM
The color indicates flashing
SU MO TU WE TH FR SA
8 30
S
AM
ON
1
P
PW
SU MO TU WE TH FR SA
c lr
ON
PW
SU MO TU WE TH FR SA
-- --
1
P
PW
Key is re-
CLR
H5F
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H5f-bH5f-fbH5f-kb

Table of Contents