Binary Data Modification; Signed Decimal Data Modification - Omron CPM2A - 11-2005 Manual

Programmable controllers
Table of Contents

Advertisement

Programming Console Operations

4-2-23 Binary Data Modification

Caution
!
1, 2, 3...

4-2-24 Signed Decimal Data Modification

This operation is used to change the status of a word's bits when the word is
monitored using the procedure described in 4-2-16 Binary Monitor. It is pos-
sible in MONITOR or PROGRAM mode only.
RUN
No
OK
Bits SR 25300 to SR 25507 and timer/counter flags cannot be changed.
Before changing the contents of I/O memory, be sure that the changes will not
cause equipment to operate unexpectedly or dangerously. In particular, take
care when changing the status of output bits. The PC continues to refresh I/O
bits even if the PC is in PROGRAM mode, so devices connected to output points
on the CPU Unit, Expansion Units, or Expansion I/O Units may operate unex-
pectedly.
1. Monitor the status of the desired word according to the procedure described
4-2-16 Binary Monitor.
(Binary monitor)
2. Press the CHG Key to begin binary data modification.
A flashing cursor will appear over bit 15. The cursor indicates which bit can
be changed.
3. Three sets of keys are used to move the cursor and change bit status:
a) Use the Up and Down Arrow Keys to move the cursor to the left and right.
b) Use the 1 and 0 Keys to change a bit's status to on or off. The cursor will
move one bit to the right after one of these keys is pressed.
c) Use the SHIFT+SET and SHIFT+RESET Keys to force-set or force-re-
set a bit's status. The cursor will move one bit to the right after one of
these keys is pressed. The NOT Key will clear force-set or force-reset
status.
Note Bits in the DM Area cannot be force-set or force-reset.
4. Press the WRITE Key to write the changes in memory and return to the
binary monitor.
WRITE
This operation is used to change the decimal value of a word being moni-
tored as signed decimal data, within a range of –32,768 to 32,767. The con-
tents of the specified word are converted automatically to signed hexadeci-
mal (two's complement format).
MONITOR
PROGRAM
OK
Bit 15
CHG
B
1
Section
4-2
Bit 00
115

Hide quick links: