Hardware requirements for operation of the T100 board

MASTER DRIVES basic units (new series from 1997 / 98)
The T100 has been approved for operation in the following MASTER DRIVES basic units:
q SIMOVERT VC with CUVC electronics board
q SIMOVERT MC with CUMC electronics board
The T100 can only be mounted in compact, chassis or cubicle converters, but not in compact PLUS units.
The following diagram illustrates the rules regarding permissible board combinations in the electronics box:
A
C
- CUVC
- CUMC
The T100 must be mounted in location 2.
A maximum of one communications board may be installed. It must be mounted in location 3.
Communications slot cards (e.g. CBP, CBC etc.) must be mounted on an ADB adapter board in slot G.
The communications board communicates directly with the T100.
− If a SIMOLINK SLB interface is used, it must be inserted in a slot on the CUVC or CUMN basic electronics
board, preferably in slot A. The SLB communicates directly with the basic unit, signal connections to the T100
can be made by means of binector/connector links.
CAUTION:
The SIMOLINK SLB interface can only operate in conjunction with T100 hardware product
version C9843...-L1-08 or later. The hardware product version is printed near the lower
backplane connector on the component side of the T100 board.
1-2
-- L O C A T I O N S --
1
3
F
G
- CBX on ADB
- SCB 1
- SCB 2
T100 Technology Board Manual for Software Module MS100 "Multi-Purpose Drive"
2
Electronics box
T100
= Data flow
= Do not use slot F
Siemens AG 6SE7087-6CX84-0BB1