Appendix; Technical Data; Revision Data - Siemens SIMOVERT FC Series Operating Instructions Manual

Masterdrives cbc - communication board can-bus
Table of Contents

Advertisement

Master Drives
CBD
01/23/98
7

Appendix

7.1

Technical data

Board name
Order No.
Rated input voltage
Operating temperature range
Storage temperature
Transport temperature
Environmental conditions
climatic class:
pollutant stressing:
Degree of pollution
Degree of protection
Mechanical strength
for stationary applications
Table 7.1
7.2

Revision data

7.2.1
Firmware Version (viewable by parameter "CB/TB diagnostics" index 26 and through
DeviceNet)
"CB/TB diagnostics"
Version 1.3
First released version
Version 1.4
There was one change in version 1.4. This change corrected a problem with the PKW data sent over the DeviceNet
network. This problem would only occur if the I/O assembly for polled I/O produced connection path ("CB parameter
1") was set to 171 (8 PZD status and actual value words) or set to 172 (16 PZD status and actual value words).
With these values for "CB parameter 1", the PKW response from the drive would normally indicate an error with the
Task ID of the response PKE = 7 even for valid requests.
Siemens AG
477 759 4070 76 J AA-74
SIMOVERT MASTER DRIVES
7 Appendix
7.1 Technical data
CBD (Communications Board DeviceNet™)
6SE7090-0XX84-0FK0
5 V 5 %, approx. 400 mA, internally from the drive
0 °C to +55 °C
25 °C to +70 °C
25 °C to +70 °C
3K3
according to DIN IEC 721 Part 3-3 / 04.90
3C2
according to DIN IEC 721 Part 3-3 / 04.90
2
DIN VDE 0110 Section 1/01.89. Moisture condensation
not permissible
IP00 DIN VDE 0470 Section1 / 11.92 =;^ EN 60529
DIN IEC 68-2-6 / 06.90
Frequency range
Hz
10 to 58
above 58 to 500
CUVC & CUMC
r732.26
Betriebsanleitung / Operating Instructions
(32 °F to 131 °F)
(13 °F to 158 °F)
(13 °F to 158 °F)
Constant amplitude of the
deflection
mm
0.075
DC-Master
CU2
n732.26
r731.26
acceleration
2
m/s
(g)
9.8 (1)
65