Instructions for the installer

4 ADAPTATION TO DIFFERENT TYPES OF GAS

Before carrying out the following operations, disconnect the appliance from the power supply.
The appliance is preset for natural gas G20 (2H) at a pressure of 20 mbar. In case of operation with
other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas
taps. In addition, in case of the gas oven burner, the primary air must be regulated (3.4.2 Primary air
adjustment for oven burner). To change the nozzles, proceed as described in the following
paragraphs.
4.1 Replacement of the cooking hob nozzles
1. Extract the pan stands and remove all the caps and flame-spreader crowns;
2. Unscrew the burner nozzles with a 7 mm socket wrench;
3. Proceed to replace the burner nozzles according to the gas to be used (see paragraph "3.2/3.3
Burner and nozzle characteristics table").
4. Replace the burners in the correct position.
The nozzles for using city gas (G110 – 8 mbar) are available from authorised service centres.
38