Smeg CX51GVE Manual page 8

Table of Contents

Advertisement

Instructions for the installer
3.4.3
Connection to the gas cylinder in the internal compartment of the appliance (only on
some models)
Open the side compartment and insert a gas cylinder of
max 15 kg. Push one end of the hose onto the hose
connector and secure it with one of the two supplied
clamps.
Insert
the
compartment via the hole located at the back of the
appliance following the diagram shown to the side. Push
the other end onto the pressure regulator of the gas
cylinder; secure it in place using the second supplied
clamp. Check for any leaks using a soapy solution,
never with a flame.
For the connection between the cooker and the gas cylinder use a portion of a standards-compliant
hose not less than 1.4 m in length.
3.4.4
Connection to liquid gas
Use a standards-compliant pressure regulator and carry out the connection to the gas cylinder in
accordance with the regulations in force.
Make sure that the supply pressure complies with the values indicated in the paragraph "3.2/3.3
Burner and nozzle characteristics table".
Screw the small hose connector F onto the large hose connector A;
connect the block thus obtained to the gas connector B (or use the hose
connector G which must be connected directly to the gas connector B)
and place the seal C in between them. Push the end of the rubber hose
H on to the hose connector A+F (or G) and to the outlet connection of
the pressure reducer on the gas cylinder. Secure the end of the hose H
to the hose connector A+F (or G) with the standards-compliant clamp I.
The hose connector G illustrated is not supplied with the appliance. Only use standards-compliant
hose connectors.
3.4.5
Connection with flexible steel hose (for all types of gas)
This type of connection can be made on both built-in and free-standing
appliances. Only use standards-compliant steel hoses whose length is
not greater than 2 metres. Screw the end of the flexible hose L, with the
seal C positioned in between, to the B threaded ½" external gas
connector (ISO 228-1).
At the end of the installation, check for any leaks with a soapy
solution, never with a flame.
hose
into
the
gas
cylinder
37