Adaptation To Different Types Of Gas - Smeg TRA93BL User Manual

Hide thumbs Also See for TRA93BL:
Table of Contents

Advertisement

When the job is complete, the installer must
issue a certificate of conformity.
1 Extraction using a hood
2 Extraction without a hood
A Single natural draught chimney
B Single chimney with extractor fan
C Directly outdoors with wall- or window-
mounted extractor fan
D Directly outdoors through wall
Air
Combustion products
Extractor fan
66
Installation
5.2 Adaptation to different types of
gas
In case of operation with other types of gas,
the burner nozzles must be changed and
the minimum flame adjusted on the gas
taps.
Replacing nozzles
1. Remove the pan stands, burner caps and
flame-spreader crowns to access the
burner casings.
2. Replace the nozzles using a 7 mm socket
wrench according to the gas to use (see
Burner and nozzle characteristics tables).
3. Replace the burners in the correct
position.
The appliance is preset for natural
gas G20 at a pressure of 20
mbar.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Csp9gmxaC92gmx9Tra4110blCs9gmxa

Table of Contents