Left Control Panel View - Dell EMC PowerEdge R640 WNW58 Installation And Service Manual

Table of Contents

Advertisement

Left control panel view

Figure 5. Left control panel with optional iDRAC Quick Sync 2.0 indicator
Table 4. Left control panel
Item
Indicator or button
1
Status LED indicators
System health and system
2
ID indicator
3
iDRAC Quick Sync
2 wireless indicator
(optional)
NOTE:
Sync 2 wireless
indicator is available
only on certain
configurations.
Status LED indicators
NOTE:
The indicators display solid amber if any error occurs.
Table 5. Status LED indicators and descriptions
Icon
Description Condition
Drive
The indicator turns solid amber if
indicator
there is a drive error.
Temperature
The indicator turns solid amber
indicator
if the system experiences a
thermal error (for example, the
ambient temperature is out of
range or there is a fan failure).
Icon
N/A
iDRAC Quick
Description
Indicate the status of the system. For more information, see the
Status LED indicators
Indicates the system health. For more information, see the
System health and system ID indicator codes
Indicates if the iDRAC Quick Sync 2 wireless option is activated.
The Quick Sync 2 feature allows management of the system
using mobile devices. This feature aggregates hardware/
firmware inventory and various system level diagnostic/error
information that can be used in troubleshooting the system.
You can access system inventory, Dell EMC Lifecycle Controller
logs or system logs, system health status, and also configure
iDRAC, BIOS, and networking parameters. You can also launch
the virtual Keyboard, Video, and Mouse (KVM) viewer and
virtual Kernel based Virtual Machine (KVM), on a supported
mobile
device.www.dell.com/poweredgemanuals
Corrective action
● Check the System Event Log to determine if the drive has an
error.
● Run the appropriate Online Diagnostics test. Restart the system
and run embedded diagnostics (ePSA).
● If the drives are configured in a RAID array, restart the system,
and enter the host adapter configuration utility program.
Ensure that none of the following conditions exist:
● A cooling fan has been removed or has failed.
● System cover, air shroud, memory module blank, or back filler
bracket is removed.
● Ambient temperature is too high.
Dell EMC PowerEdge R640 overview
section.
section.
13

Advertisement

Table of Contents
loading

Table of Contents