Dell PowerEdge R640XL Configuration Manual
Dell PowerEdge R640XL Configuration Manual

Dell PowerEdge R640XL Configuration Manual

Security analytics gen14 dell hardware by symantec

Advertisement

Security Analytics Gen14 Dell Hardware
Configuration Guide
18 Dec 2020

Advertisement

Table of Contents
loading

Summary of Contents for Dell PowerEdge R640XL

  • Page 1 Security Analytics Gen14 Dell Hardware Configuration Guide 18 Dec 2020...
  • Page 2 Security Analytics Gen14 Dell Hardware Configuration Guide Broadcom, the pulse logo, Connecting everything, and Symantec are among the trademarks of Broadcom. Copyright © 2020 Broadcom. All Rights Reserved. The term “Broadcom” refers to Broadcom Inc. and/or its subsidiaries. For more information, please visit www.broadcom.com.
  • Page 3: Table Of Contents

    Configure the Server’s iDRAC Port ..........................18 Initialize and License the Server...........................19 Configure Network Settings for the Storage Array ..................... 20 Chapter 4: Disk Array Configuration ....................21 Clear Disk Arrays on the Storage Array........................21 Configure Capture and Indexing Filesystems......................24 Gen14 Dell Hardware...
  • Page 4: Chapter 1: Introduction

    WARNING! You cannot combine Gen14 Dell hardware with Gen12 or Gen13 Dell hardware, or with SA-S500 Series servers. The Gen14 Dell hardware documented in this guide should only be used as indicated with the specified Symantec models. Requirements The Security Analytics systems documented in this guide require the following: Server ...
  • Page 5: Prerequisites (Before Using This Configuration Guide)

    Configuration Guide Prerequisites (Before Using This Configuration Guide) Before attempting to configure a Security Analytics system with Gen14 Dell hardware, make sure to first complete the following quick start guides for your server and storage array. 1. Complete the following steps to install the SA-SRVG8-20 or SA-SRVG8-20 server, per the instructions in the SA Gen14 Dell Server Quick Start Guide, available at: techdocs.broadcom.com...
  • Page 6: Server I/O Configuration

    MGMT, Ethernet (LAN), and RAID controller (SAS) ports. SA-SRVG8-20 Server Rear Panel SA-SRVG8-40 Server Rear Panel Storage Array I/O Configuration The following storage arrays can be used in Sensor Systems. They include the following MGMT and SAS ports. SA-STAG8-2U144 Storage Array Rear Panel Gen14 Dell Hardware...
  • Page 7 Security Analytics Configuration Guide SA-STAG8-5U840 Storage Array Rear Panel SA-STXG8-2X144 Expansion Enclosure Rear Panel Gen14 Dell Hardware...
  • Page 8: Security Analytics Systems

    Security Analytics Configuration Guide Security Analytics Systems The following Security Analytics systems (8.1.3 or later) are supported with the specified Gen14 Dell hardware. CM or Sensor / Space Storage Array / Space Expansion Enclosure / Space Network (1) SA-SRVG8-20 12TB –...
  • Page 9: Chapter 2: Connect The Storage Arrays

    (1) SA-SRVG8-20 + (1) SA-STAG8-2U144 Server SA-SRVG8-20 Sensor SA-STAG8-2U144 Storage Array RAID Controller Port Controller Module Port Slot 1 SAS 0 A (Top) SAS 0 Slot 1 SAS 1 B (Btm) SAS 0 Cabling Guide for Small Sensor System #1 Gen14 Dell Hardware...
  • Page 10 SAS C A (Top) SAS A B (Btm) SAS C B (Btm) SAS A A (Top) SAS C A (Top) SAS A B (Btm) SAS C B (Btm) SAS A Cabling Guide for Small Sensor System #2 Gen14 Dell Hardware...
  • Page 11 (1) SA-SRVG8-20 + (1) SA-STAG8-5U840 Server SA-SRVG8-20 Sensor SA-STAG8-5U840 Storage Array RAID Controller Port Controller Module Port Slot 1 SAS 0 A (Left) SAS 0 Slot 1 SAS 1 B (Right) SAS 0 Cabling Guide for Small Sensor System #3 Gen14 Dell Hardware...
  • Page 12: Cabling For Large Sensor Systems

    SAS 0 A (Left) SAS 0 Slot 1 SAS 1 B (Right) SAS 0 Slot 3 SAS 0 A (Left) SAS 1 Slot 3 SAS 1 B (Right) SAS 1 Cabling Guide for Large Sensor System #1 Gen14 Dell Hardware...
  • Page 13 SAS C A (Top) SAS A B (Btm) SAS C B (Btm) SAS A A (Top) SAS C A (Top) SAS A B (Btm) SAS C B (Btm) SAS A Cabling Guide for Large Sensor System #2 Gen14 Dell Hardware...
  • Page 14 SAS 0 A (Left) SAS 0 Slot 1 SAS 1 B (Right) SAS 0 Slot 3 SAS 0 A (Left) SAS 1 Slot 3 SAS 1 B (Right) SAS 1 Cabling Guide for Large Sensor System #3 Gen14 Dell Hardware...
  • Page 15 SAS 0 A (Top) SAS 0 Slot 1 SAS 1 B (Btm) SAS 0 Slot 3 SAS 0 A (Top) SAS 0 Slot 3 SAS 1 B (Btm) SAS 0 Cabling Guide for Large Sensor System #4 Gen14 Dell Hardware...
  • Page 16 SAS 0 A (Top) SAS 0 Slot 3 SAS 1 B (Btm) SAS 0 A (Top) SAS EXP A (Top) SAS A B (Btm) SAS EXP B (Btm) SAS C Cabling Guide for Large Sensor System #5 Gen14 Dell Hardware...
  • Page 17 SAS 0 A (Left) SAS 0 Slot 1 SAS 1 B (Right) SAS 0 Slot 3 SAS 0 A (Left) SAS 0 Slot 3 SAS 1 B (Right) SAS 0 Cabling Guide for Large Sensor System #6 Gen14 Dell Hardware...
  • Page 18: Chapter 3: First-Time Power On And Initialization

    Configuration Guide Chapter 3: First-time Power On and Initialization NOTE: Security Analytics 8.1.3 or later is required when using Gen14 Dell servers and storage arrays. Powering On Sensor Systems When powering on Sensor Systems, make sure that components are powered on in the following order: 3.
  • Page 19: Initialize And License The Server

    The server appliance (SA-SRVG8-20 or SA-SRVG8-40), as Central Manager (CM) or Sensor, must be initialized and licensed before it can be used in a Security Analytics system. If this has already been done per the instructions on the Security Analytics Gen14 Dell Server Quick Start Guide, it need not be done again. Initialize the Server If the server appliance (SA-SRVG8-20 or SA-SRVG8-40) has not yet been initialized, perform the following steps: 1.
  • Page 20: Configure Network Settings For The Storage Array

    Network settings for storage arrays must be configured before they can communicate with Sensors. If this has already been done per the instructions on the Security Analytics Gen14 Dell Storage Quick Start Guide, it need not be done again. Network settings for expansion enclosures do not need to be configured.
  • Page 21: Chapter 4: Disk Array Configuration

    No action was required. (2020-07-30 10:25:33) Command completed successfully. (2020-07-30 10:25:33) All of the initiators have been deleted. (2020-07-30 10:25:33) Command completed successfully. (2020-07-30 10:25:33) Command completed successfully. 4. Enter the following command to reboot the storage array: # sudo reboot Gen14 Dell Hardware...
  • Page 22 Mapping succeeded. Initiator 52cea7f043a38900 was mapped for volume capture with LUN 2. (capture) (2020-08-04 19:00:21) Command completed successfully. (capture) - Mapping succeeded. Initiator 52cea7f043a38901 was mapped for volume capture with LUN 2. (2020-08-04 19:00:21) Command completed successfully. Gen14 Dell Hardware...
  • Page 23 Mapping succeeded. Initiator 52cea7f043a16a00 was mapped for volume capture4 with LUN 5. (capture4) (2020-08-04 17:46:24) Command completed successfully. (capture4) - Mapping succeeded. Initiator 52cea7f043a16a01 was mapped for volume capture4 with LUN 5. (2020-08-04 17:46:24) Command completed successfully. 7. Reboot the Sensor and proceed immediately to the next section. Gen14 Dell Hardware...
  • Page 24: Configure Capture And Indexing Filesystems

    Capture Devices dm-0 size 93900.0 Index Devices dm-1 size 23400.0 ***************************************************************************** Run the following commands to build the capture and index volumes ***************************************************************************** mv -f /etc/solera/config/capture-config /etc/solera/config/capture-config.old mv -f /etc/solera/config/index-config /etc/solera/config/index-config.old build-ds-capture dm-0 build-ds-index -M dm-1 reboot Gen14 Dell Hardware...
  • Page 25 For the SA-STAG8-2U144, enter:  mv -f /etc/solera/config/capture-config /etc/solera/config/capture-config.old mv -f /etc/solera/config/index-config /etc/solera/config/index-config.old build-ds-capture dm-0 build-ds-index -M dm-1 For the SA-STAG8-5U840, enter:  mv -f /etc/solera/config/capture-config /etc/solera/config/capture-config.old mv -f /etc/solera/config/index-config /etc/solera/config/index-config.old build-ds-capture dm-0 dm-3 dm-2 dm-1 build-ds-index -M dm-4 Gen14 Dell Hardware...
  • Page 26 Security Analytics Configuration Guide 5. Enter the following command to reboot the storage array: # sudo reboot 6. After rebooting, enter the following command for a report of the array configuration: # df -h Gen14 Dell Hardware...
  • Page 27 2020.12.18, 11:28:23...

Table of Contents