3. Insert the end with the exhaust fitting into the
grooves of the heat exhaust port on the back of
the unit, then turn until the fitting snaps into place.
FIGURE 15
4. Snap the window fitting onto the main window
panel, either horizontally or vertically depending
on your installation.
Main window panel
Window mounting joint
FIGURE 16
Tip : To improve the cooling efficiency of your air
conditioner, the exhaust hose should be as short
and straight as possible. We suggest the configura-
tion shown in Figure 17.
Max. 60 cm (24 in)
FIGURE 17
INSTALLATION GUIDE
Grooves
The user can adjust the installation method of the
exhaust hose according to his needs. However, in-
stallation methods similar to those illustrated below
are not permitted, as they may result in uneven heat
removal and thus reduce the efficiency of the unit.
FIGURE 18
NOTES :
▪ The maximum length of the flexible hose is
less than one meter. It is recommended to use
the shortest possible length.
▪ When installing, the heat exhaust hose should
be as horizontal as possible. Do not extend it
by connecting it to other flexible hoses.
INSTALLATION OF POLYCARBONATE
PANELS (OPTIONAL)
Refer to the installation sheet included with the
polycarbonate window accessory kit for installation
in a casement window.
FIGURE 19
Polycarbonate
panel assembly