Summary of Contents for Gree GPC12AJ-K3NNA1D

  • Page 1 Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference. If you have lost the Owner's Manual, please contact the local agent or visit www.gree.com or send an email to global@gree.com.cn for the electronic version.
  • Page 2: Table Of Contents

    Content Operation and Maintenance Operation Notices Safety warning ....................... 1 Operation environment ..................2 Part's Name ......................3 Operation Guide Operation introduction for control panel ..............4 Operating methods....................5 Buttons on remote controller................... 6 Introduction for icons on display screen ..............6 Introduction for buttons on remote controller............7 Function introduction for combination buttons ............
  • Page 3 1. The appliance shall not be installed in the laundry. 2. If the supply cord is damaged, it must be replaced by the manufac- turer or its service agent or a similarly qualified person in order to avoid a hazard” 3.
  • Page 4: Safety Warning

    Safety warning ● This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory ormental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 5: Operation Environment

    Safety warning ● Keep children from playing or climbing on the air conditioner. ● Do not put or hang dripping objects above the air conditioner. ● Do not repair or disassemble the air conditioner by yourself. ● Prohibit inserting any objects into the air conditioner. Operation environment ●...
  • Page 6: Part's Name

    Part's Name Display Board Remote control receptor Air outlet Castor Handle Upper air inlet grille Heat air exhaust vent Lower air inlet grille Power cord Remote controller AUTO HEALTH X-FAN HUMIDITY FILTER TURBO HOUR ON/OFF ON/OFF MODE X-FAN TEMP TIMER TURBO SLEEP LIGHT...
  • Page 7: Operation Introduction For Control Panel

    Press once to start and press once more to stop the unit. Mode Press this button to change the operation mode as below: GPH12AJ-K3NNA1D:COOL → DRY → FAN→HEAT; GPC12AJ-K3NNA1D:COOL→ DRY → FAN→ COOL " " " " In "COOL" or "HEAT" mode, press "...
  • Page 8: Operating Methods

    Operation introduction for control panel Sleep Press sleep button to enter into sleep mode. If the controller operates at cooling mode, after sleep mode is started up, preset temperature will increase by 2°C within 2 hours and then the unit will operate at this temperature all the time; While, if the controller operates at heating mode, after sleep mode is started up, preset temperature will decrease by 2°C within 2 hours and then the unit will operates at this temperature all the time.
  • Page 9: Buttons On Remote Controller

    Buttons on remote controller ON/OFF button AUTO HEALTH X-FAN MODE button HUMIDITY FILTER +/- button TURBO FAN button HOUR ON/OFF button button ON/OFF MODE HEALTH SAVE button X-FAN button (Note: X-FAN is same with BLOW) TEMP button TIMER button X-FAN TEMP TIMER TURBO button...
  • Page 10: Introduction For Buttons On Remote Controller

    Introduction for buttons on remote controller Note: ● This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model doesn't have, if press the corresponding button on the remote controller that the unit will keep the original running status.
  • Page 11 Introduction for buttons on remote controller Note: For preventing cold wind, after starting up heating mode, indoor fan will blow fan afterdelaying 1-5min. (Details time is decided by indoor ambient temperature) Temperature setting range on remote controller: 16℃ -30℃ . Fan speed setting range: auto, low speed, medium speed and high speed.
  • Page 12 Introduction for buttons on remote controller Note: When selecting " " with remote controller, it’s auto swing. Horizontal louver of air conditioner will swing up&down automatically at the maximum angle. When selecting " 、 、 、 swing. Horizontal louver of air conditioner will stop at that position as shown by the icon to swing.
  • Page 13 Introduction for buttons on remote controller SAVE function: Under cool mode, press SAVE button and the unit will operate under SAVE mode. Dual-8nixie tube on remote controller displays "SE". Air conditioner will operate at auto speed. Set temperature can’t be adjusted. Press SAVE button again to exit SAVE mode.
  • Page 14: Function Introduction For Combination Buttons

    Introduction for buttons on remote controller hour. When holding "+" or "-" button, 2s later, the time will change quickly until to Cancel TIMER OFF: Press "TIMER" button again under TIMER OFF status. ● At OFF status, press this button once can set TIMER ON. Please refer to TIMER off for detailed operation.
  • Page 15: Operation Guide

    Operation guide 1. After putting through the power, press " " button on remote controller to ON/OFF turn on the air conditioner. 2. Press " " button to select your required mode: AUTO, COOL, DRY, FAN, MODE HEAT. 3. Press "+" or "-" button to set your required temperature. (Temperature can’t be adjusted under auto mode).
  • Page 16: Clean And Maintenance

    Clean and Maintenance Warning: ● Before cleaning the air conditioner, please turn off the unit and disconnect power. Otherwise, it may cause electric shock. ● Do not wash air conditioner with water. Otherwise, it may cause electric shock. ● Do not use volatile liquid (such as thinner or gas) to clean the air conditioner. Otherwise, it may damage the appearance of air conditioner.
  • Page 17 Clean and Maintenance Clean heat-removal pipe Remove the heat-removal pipe from air conditioner, clean and dry it , and then reinstall it. (For the method of installation and removal method, please refer to the instruction for "Installation and disassembly of heat discharge pipe"). Checking before use-season 1.
  • Page 18: Malfunction Analysis

    Malfunction analysis Please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals. Phenomenon Troubleshooting Solution ● Power failure? ● Wait after power recovery. ● Is plug loose? ● Reinsert the plug. ●...
  • Page 19 Malfunction analysis Phenomenon Troubleshooting Solution ● Whether air outlet or air inlet is ● Eliminate the obstacles. blocked? ● Under heating mode, whether ● Indoor unit will stop blowing indoor temperature is reached fan after reachingto set to set temperature? temperature.
  • Page 20 Malfunction analysis Malfunction code Disconnect powe r, and then turn on the unit Low-pressure overcurrent again after 10min. If "E5" still exits, please protection. contact professional person to maintain the unit. 1. Pour out the water inside chassis. Chassis is full of water. 2.
  • Page 21: Installation Precaution

    Installation Precaution Warning: ● Observe all governing codes and ordinances. ● Do not use damaged or non-standard power cord. ● Be caution during installation and maintenance. Prohibit incorrect operation to prevent electric shock, casualty and other accidents. Selection of Installation Location Basic requirement Installing the unit in the following places may cause malfunction.
  • Page 22: Accessories And Installation Of Heat Exhaust Hose

    Accessories and installation of heat exhaust hose ● Length range of exhaust pipe should be 50~150cm. It is recommended to use it with shortest length. ● When installing, exhaust pipe should be as flat as possible. Don't prolong the pipe or connect it with other exhaust pipe, or it would cause abnormal operation.
  • Page 23 Accessories and installation of heat exhaust hose If the pipe are to be bent, please install it by considering following dimension. 55cm 65cm 55cm Wrong installation is shown in following figure (If the pipe is bent too much, it would easily cause malfunction.)
  • Page 24: Preparation Before Installation

    Preparation before installation Note: check if the accessories are available before installation. Accessory list Window Exhaust heat discharge Front plastic unit protective grille (1) pipe pipe end Adapter Window panel Exhaust cover remote controller screw window fastener sponge A Adjustment panel Extension panel Window kit pipe clip...
  • Page 25: Installation Instructions

    Installation instructions Installation in a double-hung sash window Projection Attach the guard combined above to the window panel Push the insect guard net firmly to ensure that its four projections fit into the holes in the window panel. Cut the foam seal A (adhesive type) to Foam seal A the proper length and attach it to the (adhesive type)
  • Page 26 Installation instructions Adjustment panel If the inner width of the window is bet- ween 24" (609mm) and 36.8"(934mm) inclusive. (1) Open the window sash and place the window panel on the window stool. 24"~36.8" (2) Slide the adjustment panel to fit the window frame width.
  • Page 27 Installation instructions Installation in a sliding sash window Attach the guard combined above to the window panel. Push the insect guard net firmly to ensure that its four projections fit into the holes in the window panel. Projection Cut the foam seal A (adhesive type) to the proper length and attach it to the window frame.
  • Page 28 Installation instructions If the inner height of the window is bet- ween 24" (609mm) and 36.8"(934mm) Adjustment inclusive. panel (1) Open the window sash and place the 24"~36.8" window panel on the window frame. (2) Slide the adjustment panel to fit the window frame height.
  • Page 29 Installation instructions Cut the foam seals (adhesive type) A and B to the proper length and attach them to the window panel. Attach foam seal A to the window panel and extension panel, and attach foam seal B to the adjustment panel. Close the window sash securely Foam seal A (adhesive type)
  • Page 30 Installation instructions clasp Install rear clip — aim the rear clip(upper) at the rear clip(lower), fix them together, press the clasp forcibly in to the groove. hose rear clip Install the hose at the rear clip — aim the opening of hose at the round mouth of rear clip, rotate the hose anticlockwise into the rear clip.
  • Page 31 Installation instructions screw This length can be adjusted The length of rear plate 1 and rear according to user’s requirement plate 2 can be adjusted according to user’s requirement. Loosen the screws fixing the rear plate 1, rear plate 2 and adjustable plate to move adjustable plate the rear plate 2 and adjustable plate (can slide in the...
  • Page 32 Installation instructions Install the exhaust hose sub-assy at the rear plate — fix joint 1 of exhaust hose sub-assy at the air outlet of back plate and the groove at the two side of back plate air outlet, then insert joint 1 into the groove downwards. air outlet groove of back plate joint 1 Install baffle (air outlet) —...
  • Page 33 Installation instructions Filter 2 — hold the buckle of filter 2 to pull it outwards. buckle of filter 2 filter 2 Install wire hook — press the clasp at the upper side of back plate, assemble the first wire hook downwards into the groove of upper clasp; press the clasp at the lower side of back plate, assemble the second wire hook upwards into the groove of lower clasp.
  • Page 34: Installation Of Drainage Hose

    Installation of drainage hose ● Install of drainage hose(as shown in following figure): 1. Fix the drainage pipe clip on the right of rear side plate near drainage port with a screw. drainage pipe clip screw 2. Remove the rubber plug at drainage port. drainage port 3.
  • Page 35: Drainage Way As Follows

    Drainage way as follows ● Drainage way as follows 1. In Cool, Dry or Heat mode operating, the condensation water will be drained to the chassis. 2. When the chassis is full with water, the buzzer will give out 8 sounds and "H8" is displayed to remind user to discharge water: ●...
  • Page 36: Electric Schematic Diagram

    Electric schematic diagram The circuit diagrams above are only for reference, which are subject to change without notice. GPC12AJ-K3NNA1D: POWER BN(BK) ROOM TEMP. TUBE TEMP. OUTTUBE TEMP. BU(WH) SENSOR SENSOR SENSOR WATER MOTOR RECEIVER YEGN YEGN(GN) ROOM TUBE OUTTUBE WATER1...
  • Page 37 GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai,Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: gree@gree.com.cn www.gree.com 66166568...