ADJUSTING SETTINGS (see Figure 13)
1. Press and hold the Function Button (FB) until the Function Symbol (FS)
appears.
2. Once in the adjustment mode, press and release the Function Button (FB)
until the desired Function Symbol (FS) is displayed, see "Driver Board Quick
Reference Chart" below for function modes and settings.
3. To change Function Code (FC), press and release Toggle Button (TB) until
desired function setting is reached.
4. After changes are complete allow the driver board display to turn off.
5. Disconnect the power from the driver board for 10 seconds and then reconnect
to restart the faucet (see D-1 and E-1, Figure 4A on page 6).
NOTICE
Driver board will leave Adjustment Mode after 10 seconds of inactivity and
reset to previous settings.
FACTORY RESET
1. Press and hold the Function Button (FB) until the function symbol appears see
"Driver Board Quick Reference Chart" below.
2. Once in the adjustment mode, press and release the Function Button (FB) until
"F--" symbol is reached
3. To reset factory default settings, press and hold Toggle Button (TB) until the
'dEF' is displayed (approximiately 5 seconds) then release the Toggle Button
(TB).
4. After approximately 2-second display of "dEF", software reset will be
conducted, and the faucet will restart.
5. The functions "d", "T", "R" and "b" will be reset to the factory default settings as stated in the "Driver Board Quick Reference Chart" below.
Function
Function
Symbol
You can set the distance at which the sensor will detect hands in the wash area.
Sensor Range
d
Factory Set - 9" (23 cm) from sensor
Auto Timer is a safety mode in the event the sensor continually senses a target. In this
Auto Timer
case, the faucet will stop after the predetermined time period expires.
T
(faucet shut-off)
Factory Set - 45 seconds
This feature is meant to purge stagnant water from supply lines. The faucet will turn on
after the set amount of hours of inactivity and run the set Rinse Time (r) (see below).
R
Rinse Cycle
Factory Set - "--" (OFF)
This feature is only active if Rinse Cycle (R) time is chosen.
r
Rinse Time
The setting determines how long the faucet will turn on during the Rinse Cycle (R).
Factory Set -10 seconds (once enabled)
For Proximity, the buzzer setting does not silence the controller and sensor status
sounds. Buzzer options are ON and - (OFF), the default setting is ON.
Buzzer
b
Factory Set - On
LED will light up indicating low power.
Sensor LED
L
enable/disable
Factory Set - On
This feature changes the product into a metering faucet; it will run the full set amount of
time after the user's hands are first detected.
M
Metering Mode
Auto Timer (T) is disabled when the feature is turned on.
Factory Set - "--" (OFF)
This feature resets specific functions to factory default setting. The specific reset
Factory default
F
functions are listed as d, T, R, b and W. Each setting value refers to default setting in the
setting
column of Factory Default Setting in this table

MAKING ADJUSTMENTS

EFFECTUER DES RÉGLAGES
AJUSTES DE CONFIGURACIÓN
Driver Board Quick Reference Chart
Description
Page 23 - 39
216378, Rev. C
Figure 13
FS
MB
Function Code
3" to 15" (8 to 38 cm) from
sensor
5, 7, 10, 12, 15, 30, 45, 60,
75, 90 seconds
2.0, 3.0, 4.0, 5.0, 6.0, 7.0,
8.0, 9.0, 9.9 minutes
-- (OFF), 6, 12, 18, 24, 30,
36, 42, 48 hours
10, 20, 30, 40, 50, 60, 90
seconds
2.0, 2.5, 3.0 minutes
ON, -- (OFF)
ON, - (OFF)
-- (OFF), 7, 8, 9, 10, 11, 12,
13, 14, 15, 18, 24, 30, 40,
50, 60, 90 seconds
2.0, 2.5, 3.0, 3.5, 4.0
minutes
NA