Installation and Operation of Model 8900 VR
v)
A fold test to make certain that you are getting a good mix is
recommended. To take a fold test, take a piece of paper about 2'
long and dispense a bead of material ready for production onto the
paper. Fold the paper in two along the bead; open paper and
carefully inspect mixed material.
Materials should appear
consistent in color without any streaking.
NEXT STEP: GENERAL TROUBLESHOOTING GUIDE
15