Electric airless sprayers, for professional use only, not approved for use in explosive atmospheres or hazardous locations, for portable airless spraying of architectural paints and coatings, 3300 psi 228 bar, 22.8 mpa maximum working pressure (88 pages)
Electric airless sprayers for portable airless spraying of architectural coatings and paints - 3300 psi (227 bar, 22.7 mpa) maximum working pressure (37 pages)
Page 1
Operation Electric Airless Sprayers - For Portable Airless Spraying of Architectural Coatings and Paints - 3300 psi (227 bar, 22.7 MPa) Maximum Working Pressure IMPORTANT SAFETY INSTRUCTIONS Read all warnings and instructions in this manual. Save these instructions. ti14838a 695/795 Premium Hi ti15036a MARK V ti15034a...
Page 2
Models: Models: 695 ULTRA MAX lIl Model QuikReel Hi-Boy ✓ ✓ 258719 ✓ 258720 258722 258872 ✓ 258873 258874 ✓ 258876 ✓ ✓ 258877 ✓ ✓ 826124 ✓ 826125 826127 795 ULTRA MAX III Model QuikReel Hi-Boy ✓ ✓ 258723 ✓...
Warnings The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risks. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where appli- cable.
Page 4
Use Graco conductive or grounded high-pressure airless paint sprayer hoses. • Do not clean with materials having flash points lower than 70° F (21° C). Use water-based material or mineral spirits-type material only.
Page 5
EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Always wear appropriate gloves, eye protection, and a respirator or mask when painting. • Do not operate or spray near children. Keep children away from equipment at all times. •...
Component Identification Component Identification Premium Digital Display ON/OFF Switch ™ WatchDog Switch (not available on Mark V or Standard Units) Pressure Control Prime / Spray Valve Filter Siphon Tube Pump Bearing Housing / ProConnect 10 Drain Tube 11 Trigger Lock 12 Model/Serial Tag 13 Hose Reel ™...
Grounding The sprayer must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for the electrical current due to static build up or in the event of a short circuit. The sprayer cord includes a grounding wire with an appropriate grounding contact.
15/20 Amp Switch (Not Available on All Units) 15/20 Amp Switch ti14919a Select 15A or 20A setting based on your circuit rating. Pressure Relief Procedure 1. Turn power OFF. Wait 7 seconds for power to dissipate. ti4265a 2. Lock gun trigger safety. Remove guard and SwitchTip.
Page 9
Setup 1. Standard Units Only: Connect Graco airless hose to sprayer. Tighten securely. ti14843a 2. Standard Units Only: Connect other end of hose to gun and tighten securely. ti13031a 3. Engage gun trigger safety. ti10166a 4. Remove tip guard. ti2769a 5.
Page 10
Startup Startup 1. Turn pressure control to lowest pressure. 2. Turn power ON. ti4266a ti4266a 3. Increase pressure 1/2 turn to start motor and allow fluid to circulate through drain tube for 15 seconds; turn pressure down. 15sec 4. Turn prime valve forward to SPRAY position. Disen- gage gun trigger safety.
Switch Tip Installation 1. Use spray tip (A) to insert OneSeal guard (C). 2. Insert Switch Tip. 3. Screw assembly onto gun. Tighten. ti2710a 3A0156A Spray 1. Spray test pattern. Increase pressure to eliminate heavy edges. Use smaller tip size if pressure adjust- ment can not eliminate heavy edges.
™ WatchDog Protection System (Not Available on All Units) ™ WatchDog Protection System (Not Available on All Units) Pump stops automatically when material pail is empty. To Activate: 1. Perform Startup. ti7398a 2. Premium units with digital display: Turn WatchDog switch ON and WD ON displays. EMPTY displays/flashes and pump stops when Watchdog protection system detects an empty material pail.
Page 13
Hose Reel (Not Available on All Units) Be sure to keep your head clear of hose reel while winding up hose. 1. Make sure hose is routed through hose guide. ti13504a 2. Lift and turn pivot lock 90° to unlock hose reel. Pull on hose to remove it from hose reel.
Digital Tracking System (Not Available on All Units) Digital Tracking System Operation Main Menu Short press to move to next display. Press and hold (5 seconds) to change units or reset data. 1. Turn pressure to lowest setting. Trigger gun to relieve pressure.
Page 15
Secondary Menu - Stored Data and WatchDog Pump Protection Modes 1. Perform Pressure Relief, steps 1 - 4 if they have not already been done. 2. Turn power switch on while holding DTS button down. ti13605a 3. SERIAL NUMBER scrolls past and then serial num- ber (e.g.
Page 16
Cleanup Cleanup 1. Perform Pressure Relief Procedure (page 8), steps 1 - 4. Remove siphon tube set from paint and place in flushing fluid. Remove tip guard from gun. ti2756a NOTE: Use water for water-base paint, mineral spirits for oil-base paint, or other solvents recommended by manufacturer.
Page 17
9. Remove filters from gun and sprayer, if installed. Clean and inspect. Install filters. 10. If flushing with water, flush again with mineral spirits, or Pump Armor, to leave a protective coating to pre- vent freezing or corrosion. ti2895a Pump Armor 11.
Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.