Numeric Control Panel

The following explains the manual selection of features/functions of the
Folder using the Standard and Alphanumeric Control Panels. For
network access of these functions, refer to "AccXES Client Tools User
Guide", or the "Web Printer Manager Tool User Guide".
The Numeric Control Panel is the manual means used to communicate
with the Folder. Located on the back panel of the Folder, it contains a
red four-digit display, three buttons and two LED indicators and is
available on all folders. [See the 8825/8830 Printer Operator Manual
for Finishing Communications using the Printer User Interface.]
The buttons are used by the Operator to select the folding program and
by Service while in the diagnostic mode. The red four-digit display will
indicate Fold Program Codes and the Error/Alarm Codes, as shown in
the illustration.
XXXX
The two LED, (red and green) show the status of the folder:
− The red LED indicates when the folder is busy, when it is not ready
to fold, when it is performing a self-test, or that the alarm status is
under network control
− The green LED indicates that the folder is idle and ready to fold.
September 2001
Scroll Keys
Enter key

Alphanumeric Control Panel

The Alphanumeric Control Panel is the manual means used to
communicate with the folder, and is standard when the folder is used
with the 8855 Printer.
This control panel, which is located on the left front side of the folder,
consists of an alphanumeric display and six different buttons.
Reset key:
• Performs POST (Power On Self Test) if it is kept
pressed for less than two seconds
• Performs Manual Ejecting Procedure if kept pressed
for more than two seconds. Its activation enables
rollers to eject paper jams. To exit, wait five seconds
and then keep the Reset key pressed for less than two
seconds.
Scroll Keys
Enter Key
Pause toggle key. This is used to put the Folder in pause
mode, thereby entering into the Operator Menu.
Exit Key