Setting The Ip Address Of Interface 0 Or The System Ip - Watchguard V10 User Manual

Firebox vclass series
Hide thumbs Also See for V10:
Table of Contents

Advertisement

CHAPTER 3: Getting Started
If you have already installed and configured at least one
Firebox Vclass appliance, you can import its configuration
information into a new factory default appliance using an
XML profile. For more information, see "Exporting and
Importing Configuration Files" on page 410.
Setting the IP address of Interface 0 or the
System IP
If you are deploying the Vclass appliance in Router Mode,
you must now define a temporary IP address to interface 0
(Private) for use in the initial configuration. If you are
deploying the device in Transparent Mode, you must set
the System IP. After this is complete, you can log in with
Vcontroller and perform further configuration.
1
From the Devices Found field, select the appliance you
want to configure.
2
Click the Set Interface IP button.
3
Click Router Mode or Transparent Mode to set the
System Mode.
4
For Router Mode, in the Interface 0 IP field, type an
unused IP address from the same subnet as the
Management Station. This IP address will apply only
to Interface 0 (Private).
In the Interface 0 Mask field, type the subnet mask for
this IP address.
5
For Transparent Mode, in the System IP field, type an
unused IP address from the same subnet as the
Management Station. This IP address will apply to all
interfaces on the appliance.
32
N
OTE
Vcontroller

Hide quick links:

Advertisement

Table of Contents
loading