Carrier 40TGV0131UP Service Manual page 94

Hide thumbs Also See for 40TGV0131UP:
Table of Contents

Advertisement

No.
Part name
Control P.C.
5
1. Detachment
board
1) Carry out work of item 1 of 2.
2) Remove connectors which are
NOTE :
Unlock the lock of the housing part and
then remove the connector.
3) Unlock the locks of the card edge
2. Attachment
1) Fix the control P.C. board to the card
2) Connect the connector removed in item
3) Following to work of item 2 of 2, mount
Procedure
connected from the control P.C. board
to the other parts and then remove
wiring from the clamp.
CN510 : Louver motor (20P, White)
CN60 : Signal receiving unit
(6P, White)
CN214 : Signal receiving unit
(3P, White)
CN34 : Float switch (3P, Red)
CN504 : Drain pump (2P, White)
CN101 : TC sensor (2P, Black)
CN102 : TCJ sensor (2P, Red)
CN104 : Room temp. Sensor
(2P, Yellow)
CN333 : Fan motor power supply
(5P, White)
CN334 : Fan motor position detection
(3P, White)
spacer (4 positions) and then remove
the control P.C. board.
edge spacer (6 positions)
1 as before and then fix the wiring wit
the clamp.
the electric parts box cover and the
suction grille as before.
Card edge spacer
Card edge spacer
Card edge spacer
- 94 -
Remarks