Off–The node is not configured for clustering or it has been disabled by the dual
membership and detection recovery process in reaction to a control link or fabric link
failure.
LINK/ACT LED, one for each of the two ports CHASSIS CLUSTER CONTROL 0 and CHASSIS
CLUSTER CONTROL 1:
•
Green–Chassis cluster control port link is active.
•
Off–No link.
ENABLE LED, one for each of the two ports CHASSIS CLUSTER CONTROL 0 and CHASSIS
CLUSTER CONTROL 1:
•
Green–The chassis cluster control port is enabled.
•
Off–The chassis cluster control port is disabled.
Serial Number
The serial number label is located as shown in
Location
Figure 5: Serial Number Label (IOC Shown, Other Cards Similar)
Services Processing Card SRX5K-SPC3 Specifications
The SRX5K-SPC3 Services Processing Card (SPC) contains two Services Processing Units (SPUs) with
128GB of memory per SPU, that provide the processing power to run integrated services such as
firewall, IPsec, and IDP (see
A chassis cluster IP monitoring failure.
Figure 6 on page
20). All traffic traversing the firewall is passed to an SPU
Figure 5 on page
19.
19