AIR SHUTTER WING NUT
Figure 9.2 Air Shutter
Air Shutter Settings
MODEL
GAS TYPE
Natural
6KX-AU
Propane
ULPG
* As tested 3 ft. (914 mm) out of rear vent, 90 degree
verticle elbow, 2 ft. (610 mm) horizontal, 90 degree hori-
zontal elbow, 1 ft. (309 mm) horizontal and a DVP-TRAP2
termination cap.
SHUTTER SETTING
Min Vent Run
*Max Vent Run
5/8 in. (16 mm)
Full Open
3/4 in. (19 mm)
Full Open
Full Open
Full Open
Heat & Glo • 6KX-AU Installation Manual • 2589-980 Rev. B • 5/23
G. Service/Replace Appliance Gas Valve
• See Figure 9.3.
• Remove decorative barrier front, glass, logs, base
pan assembly, burner assembly and valve plate as-
sembly. See Figure 9.3.
• Perform service or replace gas valve.
• Reinstall valve plate assembly, burner assembly,
basepan assembly, logs and appliance glass and
front.
VALVE PLATE ASSEMBLY
FULL VALVE
ACCESS
TO REMOVE BOTTOM
SURROUND:
FLATTEN TABS
PUSH BACK AND OUT
Figure 9.3 Gas Valve Access
TABS
59