B. Decorative Barrier Front Dimension Diagrams
LOFT DECORATIVE BARRIER FRONTS
IMPORTANT! This fireplace requires an installed decorative barrier front to prevent direct contact with the
hot viewing glass. DO NOT operate the fireplace with the barrier removed.
Decorative barrier front must be ordered at time of fireplace purchase. If decorative barrier front is not
present, contact dealer.
WARNING! Risk of Overheating! DO NOT install combustible or non-combustible flooring or hearth material above
top of bottom surround. Gap between bottom of decorative front and top of bottom surround must be maintained for
proper air flow.
Note: See Section 10 for hearth, mantel and finishing requirements, including complete information for combustible
and non-combustible mantels.
BOTTOM OF MANTEL
BOTTOM OF MANTEL
TOP OF APPLIANCE
OPENING
6
LOFT-6
6
LOFT-6
Figure 3.2 Decorative Barrier Front Dimensions - LOFT
H
I
J
A
in.
34-1/4
mm
870
660
Minimum Combustible Mantel Height
at 12 In. (305 mm) Mantel Depth
(No Passive Heat)
in.
mm
Heat & Glo • 6KX-AU Installation Manual • 2589-980 Rev. B • 5/23
A
B
Barrier Mesh:
Integral to
Decorative Barrier Front
C
B
C
D
26
39-1/8
1-1/2
994
38
H
Minimum Combustible Mantel Height
at 12 In. (305 mm) Mantel Depth
19
483
G
F
D
E
E
F
4
32-7/16
101
824
I
with Passive Heat Installed
6
152
G
33-15/16
862
J
1-1/8
29
11