Product Specific and Important Safety Information

A. Appliance Certification
MODELS: 6KX-AU
LABORATORY: IAPMO OCEANA
TYPE: Gas appliances Decorative effect gas appliances
STANDARD: AS/NZS 5263.1.8
This appliance must be installed in accordance with the AS/NZS
5601.1 rules in force. PRIMARILY A DECORATIVE AND A NOT
HEATING APPLIANCE.
B. Glass Specifications
This appliance is equipped with ceramic glass with an
anti-reflective coating. Replace glass only with ceramic
glass. Please contact your dealer for replacement glass.
Inlet Gas Pressure
* Outlet (Manifold) Gas Pressure
Nonimal Gas Consumption
Burner Injector
Pilot Injector
Gas types only through field conversions.
* The allowable Outlet (Manifold) Gas Pressure ranges are: Natural Gas .78 - .95 kPa (.78 kPa nominal) and Propane,
ULPG 2.37 - 2.61 kPa (2.44 kPa nominal). Certification testing setpoint values are shown.
4
Natural Gas
1.13 - 3.40 kPa
.78 kPa
38 MJ/h
#31 DMS (3.050 mm)
Ø .023 (.584 mm)
Heat & Glo • 6KX-AU Installation Manual • 2589-980 Rev. B • 5/23
C. Gas Pressure Requirements
Pressure requirements for 6KX-AU fireplaces are shown
in table below.
Two taps are provided on the gas control for a test gauge
connection to measure the inlet and outlet pressures.
The fireplace and its individual shut-off valve must be dis-
connected from the gas supply piping system during any
pressure testing of the system at test pressures in excess
of 3.4 kPa.
If the fireplace must be isolated from the gas supply pip-
ing system by closing an individual shut-off valve, it must
be of the handle-less type.
NOTE: An inline fuel pressure regulator is recom-
mended to limit NG inlet pressure to 2.49 kPa, and LP/
ULPG inlet pressure to 3.25 kPa, to ensure optimum
product performance. The inline fuel pressure regula-
tor may be needed if any of the following symptoms
exist: pilot jetting, a highly visible pilot flame, flame
variation, etc. The inline pressure regulator should
be installed in the gas line upstream of the appliance
gas valve either at the appliance or in the utility room.
Final main and manifold gas pressure must be tested
with inline pressure regulator installed.
Propane
2.75 - 3.40 kPa
2.44 kPa
38 MJ/h
#49 DMS (1.854 mm)
Ø .014 (.356 mm)
ULPG
2.75 - 3.40 kPa
2.43 kPa
28 MJ/h
#53 DMS (1.511 mm)
Ø .010 (.254 mm)