Wiring Requirements - Heat & Glo 6KX-AU Installation Manual

Table of Contents

Advertisement

B. Wiring Requirements
IntelliFire™ Plus Ignition System Wiring
• Wire the appliance junction cord to 220/240 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction cord to a switched cir-
cuit. Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.1, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire™ Plus
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
cord to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
When using batteries as a power source, the 6-volt
transformer must be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.
RC300 REMOTE CONTROL
REM300-HNG-AU
GAS VALVE
2166-302 (N)
2166-303 (LP)
GREEN WIRE
ORANGE WIRE
Figure 8.1 IntelliFire
Plus Wiring Diagram with Remote
®
PILOT ASSEMBLY
FLAME SENSE
CONTROL
MODULE
2166-306
WIRE HARNESS
2166-304
RED WIRE
BLACK WIRE
Heat & Glo • 6KX-AU Installation Manual • 2589-980 Rev. B • 5/23
Accessories Requirements
• This appliance ships standard with a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
The junction cord, control module, LED power supply and
wall switch receiver can be accessed by removing the
vanity panel and component heat shield. The decorative
front must be removed to access these components. See
Figure 8.1.
CAUTION! Risk of Overheating! Component heat shield
MUST be installed before operating appliance. Electrical
components will be damaged.
CAUTION! Risk of Overheating! DO NOT remove com-
ponent insulation from top of component heat shield.
Electrical components will be damaged.
Note: When using PVLP-SLP-AU power vent, see
PVLP-SLP-AU instructions for additional wiring require-
ments.
2106-169 (N)
2106-170 (LP)
IGNITER
240V FAN
GFK-240V
TRANSFORMER
SRV2326-131
AUX MODULE
BATTERY PACK
2166-323
GROUND
LED CONTROL
2326-114
EMBER LIGHTING
2583-061
JUNCTION CORD
2222-037
2166-340
2589-160
55