Heat & Glo GRL-850-AU Installation And Operation Instruction Manual
Heat & Glo GRL-850-AU Installation And Operation Instruction Manual

Heat & Glo GRL-850-AU Installation And Operation Instruction Manual

Advertisement

Quick Links

INSTALLATION AND OPERATION
INSTRUCTIONS
MODEL: GRL-850-AU, GRL-850LP-AU
AUSTRALIAN GAS ASSOCIATION APPROVED AS 4558
Approval Number 7671
THIS MANUAL MUST BE USED FOR INSTALLATION AND RETAINED
BY HOMEOWNER FOR OPERATION AND MAINTENANCE.
HEAT & GLO, a brand of Hearth & Home Technologies Inc.
7571 215th Street West, Lakeville, MN 55044, U.S.A. • (952) 985-6000
Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo GRL-850-AU

  • Page 1 BY HOMEOWNER FOR OPERATION AND MAINTENANCE. HEAT & GLO, a brand of Hearth & Home Technologies Inc. 7571 215th Street West, Lakeville, MN 55044, U.S.A. • (952) 985-6000 Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10...
  • Page 2 Save this Manual for future reference. Copyright 2007 Heat & Glo, a brand of Hearth & Home Technologies Inc. 7571 215th Street West, Lakeville, MN 55044, U.S.A. Printed in U.S.A. Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10...
  • Page 3: Table Of Contents

    GAS LINE CONNECTION ................6 LOG PLACEMENT ..................7 OPERATING GUIDELINES AND MAINTENANCE INSTRUCTIONS ....10 SAFETY INFORMATION ................11 LIGHTING INSTRUCTIONS ................12 REPLACEMENT PARTS: ................13 WARRANTY POLICY ..................15  = Contains updated information. Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10...
  • Page 4 NOTE: Unit must be 33mm back from fireplace front. 33mm MINIMUM FIREPLACE OPENING Minimum Maximum WIDTH: 850mm 1050mm DEPTH: 300mm 460mm HEIGHT: 425mm 540mm 300mm DEPTH FIGURE 1 Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10...
  • Page 5: Introduction

    Immediately call a qualifi ed service technician to inspect the unit and to replace any part of the control system and any gas control which has been underwater. Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10...
  • Page 6: Gas Line Connection

    For control system wiring diagram see Figure 2. OPTIONAL WALL SWITCH, THERMOSTAT OR REMOTE TP/TH THERMOCOUPLE THERMOPILE ON/OFF REMOTE SWITCH SWITCH GAS VALVE PIGTAIL Figure 2 Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10...
  • Page 7: Log Placement

    ACCESS COVER ON/OFF SWITCH VALVE Figure 1 NOTE: Overhead view of burner, decorative front CAUTION: Logs are fragile. Carefully remove the logs from the packaging. and surround. Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10...
  • Page 8 Place log #2 on the left front corner of the grate using its locating groove and tab. STEP 5: LOG #3 (SRV2011-703) Place log #3 onto the center of the burner using its locating tabs and slot. Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10...
  • Page 9 Place log #6 in the groove on top of log #1 with its front on log #2. The left front edge of log #6 must be located 248mm from the left decorative front corner. Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10...
  • Page 10: Operating Guidelines And Maintenance Instructions

    FULL OPEN Proper means must be employed to ensure suffi cient draft. Note to Installer: Disconnect this appliance and advise owner if any spillage or abnormal operation occurs Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10...
  • Page 11: Safety Information

    • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neigh- bor’s phone. Follow the gas supplier’s instruc- tions. Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10...
  • Page 12: Lighting Instructions

    3. Turn the valve control knob clockwise 2. Turn ON/OFF switch to "OFF". to the "Pilot" position, then depress knob and continue turning to "OFF" position. 4. Replace control access cover. Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10...
  • Page 13 GRL-850-AU Service Parts Beginning Manufacturing Date: 4-2003 Service Parts Diagram Ending Manufacturing Date: ________ Log Set Assembly Part number list on following page. Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10...
  • Page 14: Replacement Parts

    ON/OFF Rocker Switch 060-521A Surround Right 2011-201 Valve N 060-524 Valve P 060-526 Shut Off Valve 2010-120 Mineral Wool 050-721 Wire Assembly 24 In 089-550A Touch Up Paint TUP-GBK-12 Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10...
  • Page 15: Warranty Policy

    Warranty Policy Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10...
  • Page 16 Warranty Policy (continued) Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10...
  • Page 17 Jetmaster 444 Swan Street Richmond 3121 (03) 9429-5573 Perth Fireplace Corner 277 Lord Street East Perth 6000 (08) 9228-2600 Sydney Jetmaster 10 Martin Avenue Arncliff 2205 (02) 9597-7222 Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10...

This manual is also suitable for:

Grl-850lp-au