Chimney Diagram - Heat & Glo 6KX-AU Installation Manual

Table of Contents

Advertisement

C. Chimney Diagram
Ref.
Below eaves, balconies or other projections
a
Appliances up to 50 MJ/h input
Appliances over to 50 MJ/h input
From the ground or above a balcony
Appliances 32 MJ/h and below
b
Appliances from 32 MJ/h to 53 MJ/h
Appliances 53 MJ/h and above
From a return wall or external corner
c
From a gas meter (M)
d
From an electricity meter or fuse box (P)
e
From a drain or soil pipe
f
Horizontally from any building structure (unless appliance approved for closer installation) or obstruction
g
facing a terminal
From any other flue terminal, cowl, or combustion air intake
h
Horizontally from an openable window, door, non-mechanical air inlet, or any other opening into a building, with the exception of sub-floor ventilation
Appliances up to 150 MJ/h input
j
All fan assisted appliances in the direction of discharge
From a mechanical air inlet, including a spa fan
k
Vertically below an openable window, non-mechanical air inlet or any other opening into a building, with the exception of See table sub-floor
ventilation
For space heaters up to 50 MJ/h input
n
For other appliances up to 50 MJ/h input
For appliances over 50 MJ/h input and up to 150 MJ/h
For appliances over 150 MJ/h input
NOTES:
1. All distances are measured vertically or horizontally along the wall to a point in line with the nearest part of the terminal.
2. Prohibited area below electricity meter or fuse box extends to ground level.
3. Flue terminal under covered area:
a) The covered area or recess shall be open on at least two sides.
b) Fan assisted flue appliance shall have at least one side open and the terminal shall be
within 500 mm of the opening and discharging in the direction of the opening.
4. Clearance from a flue terminal to a LP cylinder shall be a minimum of 1 meter.
MINIMUM CLEARANCES REQUIRED FOR BALANCED FLUE TERMINALS OR THE FLUE TERMINALS OF OUTDOOR APPLIANCES
Figure 4.5 Minimum Clearances for Termination
26
Item
Heat & Glo • 6KX-AU Installation Manual • 2589-980 Rev. B • 5/23
Minimum Clearance (mm)
Natural Draft
Fan Assisted
300
200
500
300
300
355
300
410
300
460
500
300
1000
1000
500
500
150
75
500
500
500
300
500
300
-
1500
1500
1000
150
150
500
500
1000
1000
1500
1500