IBM TS4300 User Manual page 166

Tape library
Hide thumbs Also See for TS4300:
Table of Contents

Advertisement

Table 46. Warning events (continued)
Event Code
Message Text and Description
4163
Drive sled discovery timeout
4164
Inventory has been updated due to an
unexpected empty or full slot.
4165
Bottom magazine slots in the lowermost
unit are not accessible.
4166
Drive self-test diagnostic failed
4167
Drive primary port diagnostic failed
4168
Drive encryption key path diagnostic failed. • Check the SKLM server configuration and
4173
Encryption Key Path diagnostics failed.
4174
KMIP CA certificate failure.
4175
Failed to create default logical library.
134  IBM TS4300 Tape Library Machine Type 3555: User's Guide
Details and Solution
Drive sled discovery timeout, status of Drive
sleds not available in time.
• Ensure that all modules are powered
and have the interconnect cable properly
attached.
• If this event is seen on multiple modules
or after ensuring all interconnect cables are
properly attached, ensure that the network
that the base module is connected to is
not experiencing broadcast storms or other
abnormal activity.
• Reboot or power cycle the system to
rediscover the modules.
If a move fails due to an unexpected empty or
full slot, the slot is rescanned and the inventory
is corrected.
The installed accessor does not support access
to all 40 slots in the lowermost unit. The
bottom slots in the lowermost unit are not
accessible, so only 32 slots are available.
Install an accessor that supports access to all
40 slots in the lowermost unit.
Reset Drive and run the test again. If still
failing, download drive dumps and contact
service.
• Check whether the wrap test connector is
correctly connected to the selected port.
• Reset drive and run test again.
• If the diagnostic still fails, download drive
dumps and contact service.
your network settings.
• If the diagnostic still fails, download the
library logs and contact service.
• Check the Key server configuration and your
network settings.
• If the diagnostic still fails, download the
library logs and contact service.
Check whether you provided the correct
CA certificate or the CA certificate on the
encryption server was changed.
Check that no errors occurred during the
startup and that at least one drive is present
in the library.
IBM Confidential