Table 46. Warning events (continued)
Event Code
Message Text and Description
4019
Drive Firmware bundle upgrade failed.
4020
Database was reset due to a problem that
prevented the library from powering up.
4021
Drive was hot-removed while in active
status as data transfer device.
4022
Drive in wrong position.
4025
Library test failed due to a cartridge error.
4028
Library Test failed due to incompatible
cartridge.
4029
Library Test failed - Cartridge bar code
indicates incompatibility with drive.
4030
Move cartridge operation failed due to
cartridge error.
4041
Library Verify failed because the power
supply redundancy test failed.
4044
One of the Library tests failed because
a source element or destination element
isn't accessible.
126  IBM TS4300 Tape Library Machine Type 3555: User's Guide
Details and Solution
1. Verify that the firmware file is correct for the
drives.
2. Ensure that the drives are in a healthy state
with no cartridge in the drive.
3. Retry the operation.
• If the library was restored to default settings,
restore a saved configuration by using a
previously saved config file.
• If no config file exists, then proceed in
configuring the library.
Tape drives must be disabled (powered-off)
before they are removed from the Library. In
case of hot removal, this event is created if the
drive was no active LUN master. A similar event
is defined with higher severity (critical) if the
drive was LUN master.
• Put the drive back into the library.
• Follow the "Removing a tape drive" on page
153 procedure to remove the tape drive.
A full height drive was installed to a drive bay
where it is not supported. Full high drives can
only be installed in the bottom 2 bays of a
module.
Remove the cartridge and inspect it for
damage. Retry operation with another
cartridge.
Check LTO generation for cartridge and drives.
Remove cartridges that aren't compatible to
your tape drives.
Check if Media bar code label is matching
LTO generation. Replace the label or remove
incompatible media from your system.
Remove the cartridge and inspect it for
damage. Retry operation with another
cartridge.
Ensure that all power supplies are installed
properly (two per module), and that each
power supply is connected to a valid power
source.
Verify the source and destination elements and
retry the move operation.
IBM Confidential

Advertisement

Table of Contents
loading

This manual is also suitable for:

3555

Table of Contents