Table 45. Main error events (continued)
Event Code
Message Text and
Description
2052
An open magazine was
detected in one or more
modules.
2053
An open top cover was
detected.
2054
An open bottom cover was
detected.
2055
An open unit lock was
detected.
2056
Initialization failure due to
picker push pull positioning
error.
2057
Startup failure due to shipping
lock in incorrect position.
2061
Move failed pulling cartridge
from drive.
2062
Move failed inserting cartridge
to drive.
2063
Move failed positioning picker
in front of drive.
2064
Library test failed with critical
error.
2065
Library startup failed because
of robotics initialization issue
Details and Solution
• Ensure that all magazines are inserted and properly locked.
• Don't open magazines by using the emergency release while
the library is operating and the accessor is moving.
• Ensure that the top cover is inserted and properly locked.
• Don't open top cover by using the emergency release while
the library is operating and the accessor is moving.
• Ensure that the bottom cover is inserted and properly locked.
• Don't open bottom cover by using the emergency release
while the library is operating and the accessor is moving.
• Ensure that all unit locks are properly locked.
• Don't open unit locks by using the emergency release while
the library is operating and the accessor is moving.
Check for obstructions in the horizontal pathway of the
accessor such as a cartridge that is sticking out or a cable that
is impeding progress.
1. Get access to the picker assembly and manually move the
shipping lock lever to either locked or unlocked position.
2. After the shipping lock is moved to the one of the correct
positions, restart the library.
Check for labels or cartridge misalignments that would prevent
the cartridge from coming out of the drive.
Check for labels or cartridge misalignments that would prevent
the cartridge from moving into the drive.
Check for obstructions in the vertical or horizontal pathway
of the accessor. Examples might include a cartridge that
isn't seated completely in a slot, an accessor isn't sitting
horizontally level, or a problem with the accessor spooling
cable that is impeding progress.
An unidentified failure occurred. Contact your IBM service
representative.
• Check for obstructions in the horizontal and vertical pathway
of the robotics.
• Afterward reset or power cycle system.
• If the error persists, review library events for more
information