Table 45. Main error events (continued)
Event Code
Message Text and
Description
2027
Move failed pulling cartridge
from slot.
2028
Move failed inserting cartridge
to slot.
2029
Initialization failure due to
accessor front to back
positioning error.
2032
Initialization failure due to
accessor rotation positioning
error.
116  IBM TS4300 Tape Library Machine Type 3555: User's Guide
Details and Solution
• Check for labels or cartridge misalignments that can prevent
the cartridge from coming out of the slot or drive.
• For proper operation, the accessor must be able to reach the
bottom of the library. Verify that no obstructions exist at the
bottom of the library or on the bottom cover of the library in
the path of the accessor.
1. To check for obstructions at the bottom of the library, first
power off the library by pressing Power for 5 seconds and
select the Default Park location.
2. When the library is powered off, remove the left magazine
of the lowest library module, and verify that the entire
area of the bottom cover is free of any objects that might
obstruct the accessor's path.
3. After obstructions are cleared, replace the magazine, power
the library on, and after the library finishes initialization
and inventory, verify that no further critical events were
generated.
• Check for labels or cartridge misalignments that can prevent
the cartridge from coming out of the slot or drive.
• For proper operation, the accessor must be able to reach the
bottom of the library. Verify that no obstructions exist at the
bottom of the library or on the bottom cover of the library in
the path of the accessor.
1. To check for obstructions at the bottom of the library, first
power off the library by pressing Power for 5 seconds and
select the Default Park location.
2. When the library is powered off, remove the left magazine
of the lowest library module, and verify that the entire
area of the bottom cover is free of any objects that might
obstruct the accessor's path.
3. After obstructions are cleared, replace the magazine, power
the library on, and after the library finishes initialization
and inventory, verify that no further critical events were
generated.
1. Check for obstructions in the pathway of the accessor such
as a cartridge that is sticking out.
2. Verify the module alignment and frame alignment. Check
whether the accessor is stuck in lock mechanism.
3. Move the accessor apart from lock mechanism and enable
lock mechanism correctly.
Check for obstructions in the vertical pathway of the accessor,
such as a cartridge that is sitting in the shuttle of the accessor
or any other impedance to accessor movement.