3.2.7 Wiring of the DC reactor connection terminals P/+, P1

These terminals are designed for connection of the power factor improving reactor (FR-BEL).
Remove the jumper across the terminals P/+-P1 and connect the DC reactor.
The wiring distance (overall length) should be within 5m.
NOTICE
Without removal of the jumper, the reactor will not be active.
MEMO

3.2.8 Wiring of the brake resistor connection terminals P/+, PR

These terminals are designed for connection of the heavy-duty brake resistor.
1) Remove the screws in the terminals PR and PX and disconnect the jumper.
2) Connect the brake resistor to the terminals P/+, PR.
FR-AX520-0.5K, 1.0K
Terminal PR
Terminal P/+
3) Change the Pr. 30 and Pr. 70 settings.
Always remove the jumper across the terminals PR-PX.
NOTICE
Connect only the specified brake resistor.
P1
P/ +
Remove
jumper.
Terminal PR
Jumper
Terminal PX
FR-AX520-1.5K to 3.5K
Terminal P/+
Terminal PR
3-8
Get other manuals https://www.bkmanuals.com
FR-BEL
3. WIRING

Advertisement