SYSTEM PARAMETERS PROG-G
Infinite 816
Key
Telephone System
System Parameter8 ProgramminQ (Cont'dl
730.4
LOUD BELL CONTROL
ROE
. g Steps
lf the system
is in the Programrmng
mode,
continue
using program
codes.
If starting
to
program
here,
enter
the Programming
mode
first (See Paragraph
700.4).
To program
these assignments:
a. Dial an asterisk
[*I and [28] on the dial pad.
b. First, press the station
button
of the sta-
tion to be assigned
ringing
&ED will light).
c. Press HOLD to enter data
Description
The Zrsffnite 816 System provides
relay contact
closure
for activation
of external
signaling
equipment
during
incoming
CO line ringing.
The Loud Bell Control
is selected
by program-
ming in the customer
database.
Either or both of the Loud Bell Control
circuits
may be assigned
to a station.
The Loud
Bell
Control
dry contacts
will
follow
the
ringing
condition
of that
station.
Locate
the LBClT
and LBC 1R terminals
on the connecting
block.
Two wires are connected
to these terminals
and
routed
to customer
provided
signaling
equip-
ment.
All incoming
CO lines assigned
to ring for the
programmed
Loud Bell Control
station
will ac-
tivate the Loud Bell Control
station
will activate
the Loud Bell Control,
causing
the LBC con-
tacts to sequence
in a 1 second
ON/3
seconds
OFF rate until aJl lines have been answered
by
Key Telephone
users.
The LBC contacts
are
current-rated
at 1 ampere/24Vdc.
Default:
By default,
none are assigned.
730-6
Issue 1, January 1992

Advertisement