    TABLE OF CONTENTS SAFETY INSTRUCTIONS ...................1 UPS Safety Notes ...............................1 Special Symbols ..............................1 Personal Safety ..............................1 Product Safety ..............................3 INTRODUCTION ....................4 Smart APP Online UPS Systems .........................4 UPS Extended Battery Modules ........................4 Unpacking Procedures ............................4 UPS Models .................................4 What’s In The Box .............................5 OVERVIEW ......................
  • Page 3: Safety Instructions

    SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. UPS SAFETY NOTES Install and use the UPS in the following environments: • Temperature: 32°F - 104°F (0°C - 40°C); relative humidity: 0% to 95% •...
  • Page 4 SAFETY INSTRUCTIONS When installing the equipment, ensure that the sum of the leakage current of the UPS and the connected equipment does not exceed 3.5mA. Do not unplug the unit from AC power during operation, as this will disconnect the protective ground insulation.
  • Page 5: Product Safety

    IMPORTANT SAFETY INSTRUCTIONS PRODUCT SAFETY RISK OF ELECTRIC SHOCK The battery can power hazardous components inside the unit, even when the AC input power is disconnected. The UPS should be placed near the connected equipment and easily accessible. (Non-Isolated Battery Supply): Risk of electric shock, battery circuit is not isolated from AC power source;...
  • Page 6: Introduction

    INTRODUCTION SMART APP ONLINE UPS SYSTEMS CyberPower Smart App Online rack/tower UPS systems, with double-conversion topology, provide sine wave output to mission-critical applications and equipment requiring seamless power correction. These units offer generator compatibility and deliver clean AC power with zero transfer time.
  • Page 7: Whats In The Box

    INTRODUCTION WHATS IN THE BOX CONTENT CONTENT 8 Pan head screws: M5X12L 9 Plastic washers 2 Rackmount left rail 10 Screw hole dust covers 3 Rackmount right rail 11 Binding head screws: M4X6L 4 Rackmount ears 12 Truss Head Screws: M3X6L 5 User’s Manual 13 EPO Connector Pin 6 USB communication cable...
  • Page 8 INTRODUCTION WHATS IN THE BOX (FOR SELECTED MODELS) I/P-L I/P-N O/P-L O/P-N CONTENT COMPATIBLE MODELS OLS6KERT4UA-FR/GR/IEC/UN, OLS6KERT4UMA, OLS6KERT5U Output Power Cord (C13-C14) OLS10KERT4UA-FR/GR/IEC/UN, OLS10KERT4UMA, OLS10KERT5U OLS6KERT4UA-FR/GR/IEC/UN, OLS6KERT4UMA, OLS6KERT5U Output Power Cord (C19-C20) OLS10KERT4UA-FR/GR/IEC/UN, OLS10KERT4UMA, OLS10KERT5U OLS6KERT4UMA, OLS10KERT4UMA, UPS Input Cable...
  • Page 9: Overview

    OVERVIEW FRONT PANEL OLS6KERT4U/OLS10KERT4U OLS6KERT5U/OLS10KERT5U 1 . Power Button / Power on Indicator Master ON/OFF switch for the UPS. Indicates that the UPS is on and supplying power. 2 . Function Buttons Scroll DOWN scroll UP, ENTER, and ESCAPE. 3 . UPS Status / Multifunction LCD Readout Shows UPS status, information, settings and events.
  • Page 10: Rear Panels

    Enables an emergency UPS power-off from a remote location. 9 . Extended Runtime Battery Module Connector RELAY OUTPUT Connection for additional CyberPower Battery modules. 10 . Input Circuit Breaker Provide input current overload and fault protection. 11 . Terminal Block BATT DET.
  • Page 11 OVERVIEW REAR PANELS RELAY OUTPUT BATTERY INPUT RELAY OUTPUT BATTERY INPUT INPUT BREAKER INPUT BREAKER BATT DET. RS232 BATT DET. RS232 PARALLEL PORT PARALLEL PORT IN-L IN-N OUT-L OUT-N IN-L IN-N OUT-L OUT-N 250V~ 250V~ 250V~ 250V~ 250V~ 250V~ 250V~ 250V~ OLS6/10KERT4UA-FR OLS6/10KERT4UA-GR...
  • Page 12: Installing Your Ups System

    INSTALLING YOUR UPS SYSTEM SYSTEM BLOCK DIAGRAM BYPASS Input Inverter Output Input Output AC/DC Filter DC/AC Filter Charger Battery AC/DC Module Control & USB&DB9 Monitoring SNMP Slot Line Mode Battery Mode Bypass Mode Control Signal HARDWARE INSTALLATION GUIDE 1 . Battery charge loss may occur during shipping and storage. Before using the UPS, it’s strongly recommended to charge batteries for four hours to ensure the batteries’...
  • Page 13: Hardware Installation

    UPS generates an alarm and shuts down to avoid unexpected equipment damage. When the over temperature occurs, please check the Troubleshooting section. If the condition persists, please contact CyberPower for technical support. HARDWARE INSTALLATION This UPS can be installed in a rackmount or vertical/tower orientation. This versatility is especially important to growing organizations with changing needs that value having the option to position a UPS on the floor or in a rackmount system.
  • Page 14: Rackmount Installation

    INSTALLING YOUR UPS SYSTEM RACKMOUNT INSTALLATION RISK OF FALLING EQUIPMENT • The UPS is very heavy. Please handle with care. • Always practice safe lifting techniques adequate for the weight of the equipment. • The battery packs are heavy. Remove the battery packs before installing the UPS is recommended.
  • Page 15 INSTALLING YOUR UPS SYSTEM Step 5: Rackmount Ears Installation Attach two rackmount ears to the UPS using eight M4X8 flat head screws. Step 6: Rackmount Rail Installation The mounting depth of the included rackmount rails can adjust from 20.5 in to 36 in (52 cm to 91.5 cm).
  • Page 16 INSTALLING YOUR UPS SYSTEM Step 7: Place and Secure the UPS on the Rails Place the UPS on a flat stable surface with the front of the unit facing toward you. Secure the UPS to your rack with four M5X12L screws at the front of the rack. (square holes 2 and 5 as shown).
  • Page 17: Vertical/Tower Installation

    INSTALLING YOUR UPS SYSTEM VERTICAL/TOWER INSTALLATION Step 1: Attach the Base Stands Stand the UPS system on its side and attach the tower stands (rackmount ears) using four M4X8L screws onto the bottom of the UPS. Please make sure that the LCD panel is on the top of UPS when installing in tower type. Step 2: Attach the Dust Covers Insert the dust covers into the open screw holes on top and side cover.
  • Page 18 INSTALLING YOUR UPS SYSTEM Step 3: Rotate the LCD Module without Tools When connecting EBM(s), please follow the diagram to install your UPS and EBM(s) in tower type. Use rackmount ears and four M4X8L screws to fix UPS and EBM(s) when installing in tower type.
  • Page 19: Electrical Installation

    For safety, please cut off the mains power switch before installation. When installing the electrical wiring, please note the nominal amperage of your incoming feeder. Use cable cross section and protective device specification: OLS6KERT4UA/ OLS10KERT4UA/ Model OLS6KERT5U...
  • Page 20: Charging Current Setting Guide

    ELECTRICAL INSTALLATION CHARGING CURRENT SETTING GUIDE Considering the safety issue for the UPS, the setting guide for charging current are as below, Connected EBM number(s) Available Setting of Charging Current 1A, 2A 1A, 2A, 3A > 2 1A, 2A, 3A, 4A...
  • Page 21: Maintenance Bypass Power Distribution Unit (Mbp)

    MAINTENANCE BYPASS POWER DISTRIBUTION UNIT (MBP) *For Selected Models Only Maintenance Bypass PDUs allow the seamless transfer of an electrical load from UPS power to utility power for uninterrupted operation of connected equipment when performing maintenance, replacing batteries, or installing a new UPS. The UPS draws input power from the MBP through a dedicated receptacle which is separate from the outlets for connected devices.
  • Page 22: Detachable Maintenance Bypass Pdu

    MAINTENANCE BYPASS POWER DISTRIBUTION UNIT (MBP) DETACHABLE MAINTENANCE BYPASS PDU The OLS6/10KERT5U models are shipped with the installed MBP63AHVIEC82U, but the MBP also can be installed in rackmount separately. Step 1: Loosen four thumb screws from the MBP, the MBP could be detached from the UPS. Step 2: Attached two L-shaped Plates to the MBP by using four M3X6L round head screws.
  • Page 23: Using The Ups System

    USING THE UPS SYSTEM DRY CONTACT AND EMERGENCY POWER OFF RELAY OUTPUT RELAY OUTPUT Relay Output Connector Convert UPS signals into real potential-free Dry Contacts for industrial control. This UPS offers users the solution for UPS status monitoring via output relays. UPS status which can be monitored by dry contact is listed below, UPS Status UPS Conditions...
  • Page 24: Lcd Description And Display Functions

    USING THE UPS SYSTEM LCD DESCRIPTION AND DISPLAY FUNCTIONS LCD Panel and Buttons ICON ZONE CONTENT ZONE TOPOLOGY ZONE ITEM BUTTON FUNCTION DESCRIPTION ON/OFF Press this button for at least 3 seconds to turn on and off UPS. DOWN Press this button to scroll down in the LCD menu. Press this button to scroll up in the LCD menu.
  • Page 25 USING THE UPS SYSTEM UPS Modes of Operation and Topology: UPS MODE/ MODE/STATUS DESCRIPTION UPS TOPOLOGY: MODE DISPLAY STATUS (ICON) UPS is operating in Line Mode. The UPS is operating and protecting the equipment normally. UPS is operating in Battery Mode. A utility power failure has occurred.
  • Page 26: Function Tree

    USING THE UPS SYSTEM FUNCTION TREE UPS STATUS Output Voltage MAIN MENU Output Frequency Output Load (%) CONFIGURATION TEST EVENT LOGS INFORMATIONS Output Current Output Voltage Battery Test UPS Model Name Output Watt Event 01 UPS Rating Sync Frequency Window Alarm Test Output VA Event 02...
  • Page 27: Ups Status

    USING THE UPS SYSTEM UPS STATUS There are 13 types (7 pages) of UPS status readout available for display. Press "UP" and "DOWN" buttons to scroll through the UPS Status items shown in the table below. Item Display Description Output Voltage Displays the Output Voltage and O U T P U T : and Frequency...
  • Page 28: Configuration

    USING THE UPS SYSTEM CONFIGURATION There are 30 UPS items that can be configured by the user. 1. Press the “ENTER” button to enter the “Main Menu” layer. 2. Press the “UP” and “DOWN” buttons to scroll to the “Main Menu”. 3.
  • Page 29 USING THE UPS SYSTEM Available Settings Setting Item & Description LCD Display (* = default setting) Manual Bypass When performing UPS maintenance, user can manually transfer the connected load [Disable]*, [Enable] to Bypass without interrupting the output to the connected equipment. C06 Manual Bypass ECO Mode Sets the ECO operation for the UPS.
  • Page 30 USING THE UPS SYSTEM Available Settings Setting Item & Description LCD Display (* = default setting) Sets [EPO] (Emergency Power Off) to shutdown the UPS remotely when the Signal Inputs contact is close. Sets [ROO] (Remote On/Off) to turn [Disable]*, [EPO], [ROO] On the UPS remotely when the contact is close and turn Off the UPS remotely when the contact is open.
  • Page 31 EBM Number battery module(s) or allows the number of external battery module(s) with [Autodetect]*, [0-10 pack(s)] autodetect. Autodetect is used only for CyberPower EBMs. If more than 3 EBMs C25 EBM Number are connected, auto-detection does not funtion. Battery Replace Date...
  • Page 32 USING THE UPS SYSTEM Available Settings Setting Item & Description LCD Display (* = default setting) Low Capacity Warning [10%], [15%], [20%]*, [25%], Alert when the UPS supplies battery [30%], [35%], [40%], [45%], power and the remaining capacity is [50%], [55%], [60%], [65%] lower than this threshold.
  • Page 33: Test

    USING THE UPS SYSTEM Test There are 4 UPS Diagnostic items that can be tested by the user. 1 . Press the “ENTER” button to enter the “Main Menu” layer. 2 . Press the “UP” and “DOWN” buttons to scroll to the “Main Menu”. 3 .
  • Page 34: Event Logs

    USING THE UPS SYSTEM Event Logs The UPS will record the 20 most recent system events (faults) in the Event Logs. 1 . Press the “ENTER” button to enter the “Main Menu” layer. 2 . Press the “UP” and “DOWN” buttons to scroll to the “Main Menu” items. 3 .
  • Page 35 USING THE UPS SYSTEM Event Logs Cont. Event Event Content LCD Display Description Code ROO Off 27 ROO Off The UPS has been turned off by ROO. Inverter Fault 30 Inv Fault The inverter has malfunctioned. High Output The UPS has detected Inverter voltage 31 High O/P Volit Voltage too High.
  • Page 36: Information

    USING THE UPS SYSTEM Information 1 . Press the “ENTER” button to enter the “Main Menu” layer. 2 . Press the “UP” and “DOWN” buttons to scroll to the “Main Menu”. 3 . Press "ENTER" button to enter the "Informations". 4 .
  • Page 37 USING THE UPS SYSTEM Information Cont. Number Item LCD Display Description Display the network IP address. A D D R E S S IP Address *This is only shown when the RMCard has been connected. Display the network Subnet Mask. S U B N E T M A S K Subnet Mask...
  • Page 38: Maintenance

    Please dispose and/or recycle your UPS and batteries in accordance with local regulations. BATTERY REPLACEMENT For battery procurement, go to www.CyberPower.com, or contact your local dealer. When the LCD displays Service Battery, use PowerPanel Business Agent software or log on to the RMCARD to perform a runtime calibration to verify battery capacity is sufficient and acceptable.
  • Page 39 MAINTENANCE Please read and follow the Safety Instructions before servicing the battery. Battery replacement should be performed by trained personnel who are familiar with the procedures and safety precautions. Make a note of the Replacement Battery part number. • NOTE: Before replace battery packs, please make sure that the form factor of the UPS is installed as rack type.
  • Page 40 MAINTENANCE Step 5: Re-install the Battery Packs Step 5-1 : Put the new battery trays into the compartment. Step 5-2 : Re-install the battery compartment cover and the plastic sheet by tightening the screws. Please make sure the connection is properly seated. Step 5-3 : Connect the battery connectors and secure them to the battery compartment.
  • Page 41: Technical Specifications

    TECHNICAL SPECIFICATIONS Models OLS6KERT4UA OLS10KERT4UA OLS6KERT5U OLS10KERT5U CONFIGURATION Capacity (VA) 6000 VA 10000 VA 6000 VA 10000 VA Capacity (Watts) 6000 W 10000 W 6000 W 10000 W Form Factor Rackmount/ Tower Energy-saving ECO Mode Efficiency > 98% Technology INPUT 180V-300V @ >75% Load ±...
  • Page 42 TECHNICAL SPECIFICATIONS Models OLS6KERT4UA OLS10KERT4UA OLS6KERT5U OLS10KERT5U Recharge Time 0-90% 4 hours (Typical) Sealed, Maintenance Free User Replaceable STATUS INDICATORS LCD Screen Multi-Function Color TFT-LCD Readout Audible Alarms Battery Mode, Battery Low, Overload, UPS Fault MANAGEMENT & COMMUNICATIONS On-Device Features...
  • Page 43: Troubleshooting

    The Battery has connector and check 01 Over Battery is Over Charge been charged charger voltage. Charge overcharged. too High voltage. Contact CyberPower for assistance. Remove battery The Battery connector and check Charger 02 Chgr Charger has Charger has failed. charger voltage.
  • Page 44 Inverter 30 Inv The inverter has turn off input breaker. Inverter has failed. Fault Fault malfunctioned. Contact CyberPower for assistance. Shut down UPS and The UPS has turn off the input High Output 31 High detected Inverter Inverter voltage is breaker.
  • Page 45 Shut down Fan Error detected a fan Error failed. UPS and turn off the malfunction. input breaker. Contact CyberPower for assistance. Shut down UPS and The UPS has Internal DC bus turn off the input BUS Fault 41 BUS...
  • Page 46 EEPROM Fail Fail and recheck the UPS Fail condiction. If the UPS still has Eeprom fail warning, please contact CyberPower for assistance. Shut down UPS and The UPS has The UPS has turn off the input U2 ADC ADC Fail...
  • Page 47 Cyber Power Systems, Inc. www.cyberpower.com 11F., No.26, Jinzhuang Rd., Neihu Dist., Taipei City 114, Taiwan Entire contents copyright © 2023 Cyber Power Systems, Inc., All rights reserved. Reproduction in whole or in part without permission is prohibited. PowerPanel Business and PowerPanel Business are trademarks of...