Grounding Terminal

Warning: To operate the WS-AP3765 and WS-AP3767e safely, the chassis ground connector must
have a suitable cable connected to it. Do not use the AP without a connected ground cable.
The chassis ground connector is located on the rear of the device (M4 thread). Connect the ground
cable before you mount the AP on the wall or on the optional mounting plate. Once the AP is
mounted, the connector is no longer accessible.
Place the supplied toothed washer directly on the rear of the device before screwing on the ground
cable. This ensures that there is maximum contact with the screwed-on cable.
Side View of Outdoor Access Point with Cables Entering from Different
Figure
2-2). The housing of the WS-AP3765
Figure
2-2). There is an opening at the
Figure
Enterasys Wireless Outdoor Access Points Installation Guide 2-3
Attaching Cables
2-2). Mount the AP so that