Deleting instructions
Let's return for a moment to Timer 00. For practice, let's delete it from the
program using the following procedure.
First, go to address 0008. Then key in
pall)
This eliminates the TIM instruction and moves the next instruction (LD, in
this case) into the 0008 address location.
This function is useful when you wish to modify or correct an existing
program.
inserting instructions
Inserting an instruction somewhere in a program is almost as easy. Let's
assume that we now realize it was a mistake to eliminate Timer 00 from
the program. To put it back into the program, we follow this six-step insert
procedure.
1. First key in
This takes you to the first address of the memory.
2. Then key in the number of the address where you wish to make the
insertion.
Ea
3. Press
4. And then
DE
to move the program down one step, reserving address 0008 for the TIM
instruction.