• A new project has been created or an existing project is open.
• An S200 drive has been created in the project.
• For activated user management (UMAC):
The function rights for editing drive data are activated for your user account.
Details on this topic are provided in Chapter "Security settings in Startdrive" of Industrial
Cybersecurity Configuration Manual
109810578).
Procedure
1. Select the converter in the device view and open the inspector window.
2. In the secondary navigation of the inspector window, select the desired detail menu (see the
table above).
3. Make the required detail settings in the white fields. Default settings are usually available in
most detail menus.
The gray fields are corrected automatically in accordance with their setting. Fields with a gray
background cannot be edited directly.
Result
You have made the detailed settings for the converter in your device configuration.
8.5.1.4

Specifying a motor

Overview
The drive that has just been inserted in the project has a placeholder for the required motor
(standard motor type: "1FL2"). You must specify this placeholder in the configuration.
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Settings
Option "Synchronize with NTP server"
If the drive is connected to a controller in the device configuration, the option "Use PLC as
NTP server" is activated automatically.
If the drive is connected to a PLC, the IP address of the PLC is displayed. In this case, the IP
address and the time zone of the NTP server can be changed.
Option "No synchronization"
In this case, NTP synchronization is not managed in the project. You can configure this
synchronization separately for the drive in online mode with the Online & Diagnostics
function "Set time".
Supply voltage
Enabling access to the PROFINET interface [X150] and the service interface [X127] via HTTP
or HTTPS.
8.5 Combining and configuring devices in the project
(https://support.industry.siemens.com/cs/ww/en/view/
Commissioning (Startdrive)
241