Overview" Function View; Offline Mode - Siemens SINAMICS SIMOTICS S200 PROFINET Operating Instructions Manual

Servo drive system
Table of Contents

Advertisement

Commissioning (Startdrive)
8.6 Carrying out guided quick startup
3. If you want to perform extended settings, click the "Extended settings" button.
The "Machine property" dialog opens. You obtain information about the conditions under
which you can increase the speed control dynamic performance. If you wish to increase the
dynamic response, activate option "Set the current setpoint filter with loop compensation".
4. Establish an online connection to the converter if up until now you had worked in the offline
mode.
– Activate master control.
– Start the OBT.
– Check the optimization results.
– Deactivate the master control.
5. Click on "Next" to display the next quick startup step.
Result
The result of the optimization is displayed in the "Status" area. The "Optimization result" list
compares the settings changed by the optimization with the earlier settings prior to
optimization.
If optimization was not successful, repeat the optimization, possibly with modified data.
More information
For more information about One Button Tuning, see Section "Performing One Button Tuning
(Page 291)".
8.6.10

"Overview" function view

8.6.10.1

Offline mode

Overview
After completing the commissioning steps in the guided quick startup, here, you will find a
compilation of all settings that were made offline.
If necessary, you can load the settings made offline from the "Overview" function view into
the device.
274
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB