Commissioning (Startdrive)
8.5 Combining and configuring devices in the project
Result
The current device is replaced by the required replacement device.
If the two devices are not completely compatible with one another, then in the "Device view"
tab, the placeholder for the motor is displayed unspecified. You must reassign an appropriate
motor power.
8.5.1.3
Making detailed converter settings
Overview
You can configure the following details for the converter:
Table 8-1
Detailed converter settings in the inspector window
Group
General
PROFINET interface [X150]
Module parameters
Protection & Security
Ethernet commissioning in‐
terface [X127]
240
Settings
•
Product information
Name data
•
Catalog information
Brief description, description of the components included, firmware version used
•
Identification & Maintenance
Information and data to identify and localize a drive within a plant or system.
•
General
•
Ethernet addresses
Subnet, IP address, subnet mask, PROFINET names
•
Telegram configuration
– Telegrams of the closed-loop drive control: Send, receive
Details are contained in Chapter "Configuring telegrams (Page 285)"
•
Advanced options
– Interface options
– Media redundancy
– Clock cycle synchronization for local modules (isochronous mode)
– Real time settings
– Port [X150 P1] and port [X150 P2]
•
Activation of channel diagnostics
•
Wizard for security settings
•
User Management & Access Control (UMAC)
•
Ports and protocols
•
Encryption of drive data
Note: Information about these protection settings is provided in the Configuration Manual
SINAMICS Industrial Security or in the information system of the TIA Portal.
•
General
•
Ethernet addresses:
– Subnet, IP address, subnet mask