1
Safety notes
DANGER
Danger to life if the safety instructions and operating instructions are not observed
The compact operating instructions only contain the most important information for operating the converter. If the safety
instructions and operating instructions in the associated documentation are not observed, accidents involving severe
injuries or death can occur.
•
Observe the safety instructions and operating instructions given in the associated documentation.
2
Technical data
2.1
Technical data of the converter
2.1.1
Permissible climatic conditions for the converter
Feature
Climatic
Surrounding
environmental
air
conditions
temperature
Humidity
Mechanical
Vibration
environmental
conditions
Shock
Biological environmental
conditions
Protection against chemical
substances
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
A5E52388930A AA, 07/2023
Usage phase
Long-term storage
-40 °C ... +70 °C
≤ 95%, condensation not
permissible
Class 1M2 according to
IEC 60721-3-1
-
Class 1B2 according to
IEC 60721-3-1
Class 1C2 according to
IEC 60721-3-1
Transport
-40 °C ... +70 °C
≤ 95% at 45 °C
Class 2M3 according to
IEC 60721-3-2
•
2 Hz to 9 Hz: 7.5 mm
deflection
•
9 Hz to 200 Hz: 2 g
vibration
-
Class 2B2 according to
IEC 60721-3-2
Class 2C2 according to
IEC 60721-3-2
Operation
0 °C ... 55 °C, > 45 °C with
power derating
≤ 95%, condensation not
permissible
Class 3M1 according to
IEC 60721-3-3
•
10 Hz to 58 Hz: 0.075 mm
deflection
•
58 Hz to 200 Hz: 1 g
vibration
Class 3M1 according to
IEC 60721-3-3
•
Peak acceleration: 5 g
•
Duration of shock: 30 ms
Class 3B1 according to
IEC 60721-3-3
Class 3C2 according to
IEC 60721-3-3
3