On-board help
Tap (1) and select machine material. The related linear thermal expansion is shown. Enter the
three values [2] required to calculate the thermal growth value for the selected feet pair. Use
the onscreen keyboard [3] which comes into view when any one of the three value boxes [2]
is tapped. The three values are:
Ambient temperature (initial temperature)
l
Machine running temperature (final temperature)
l
Distance from machine base (or shimming plane) to the shaft centerline (length)
l
With thermal growth values enabled [4], the corresponding machine within the mini train inset
at the top-right corner is shown in orange [5].
Tap
to simultaneously display the calculated thermal growth value for the respective
feet pair [6] and toggle to the next feet pair [7].
Tap
to return to the thermal growth screen showing the calculated values.