4.5 - ALARM CONDITIONS

!
Wire tamper ( via the self-powered siren).
!
Ignition attempt.
!
Power drain (if enabled during programming. It can only be used in
countries where the use of this sensor is not prohibited).
!
Door tamper.
!
Boot tamper.
!
Bonnet tamper.
!
Motion detection by internal ultrasound volumetric sensor.
!
Motion detection detected by external sensors (optional, wireless sensor).
!
Panic alarm by pressing remote control button 2 (if enabled during
programming and only in countries where it is legal to do so). Not available
on products for the Dutch market).
NB:
In order to filter noise and/or undesired signals, IGNITION, DOOR/BOOT
SWITCH inputs have a DEBOUNCE time of 200ms. These inputs will therefore
generate an alarm cycle only if the incoming signal lasts longer than 200ms.
An alarm event will trigger alarm acoustic signals (if enabled) and the flashing
of the turn indicators for up to 30 sec.The LED will turn ON steady.
An alarm event can generate up to 5 alarm cycles, for each input and for each
arming cycle, that will last 30 seconds each.
Ignition attempts and wire tamper alarms have no limitations.

4.6 - ALARM CYCLE

Alarm events will trigger the turn indicators and the alarm siren for up to 30 sec.
according to configuration:
ADDITIONAL SIREN:
Continuous audible signal for the entire duration of the
alarm cycle.
ORIGINAL HORN:
Intermittent sound, 2" ON - 2" OFF, for the entire duration of
the alarm cycle.
The LED will be ON steady.
The alarm cycle can be interrupted without disabling the system by pressing
remote control button 2. Optical
/acoustic
and the system will be in "NEUTRAL TIME BETWEEN SUCCESSIVE
ALARMS".
To limit acoustic pollution, each input (DOOR/BOOT/BONNET SWITCHES,
ABSORPTION SENSOR, INTERNAL VOLUMETRIC SENSOR and
EXTERNAL SENSORS) will only trigger the alarm 5 times per activation cycle.
Countdown will be reset upon the next disarming of the alarm system or if an
IGNITION ATTEMPT alarm is triggered during the same activation cycle.
PAGE 6
signals will be immediately cut off,

4.7 - NEUTRAL TIME BETWEEN ALARM CYCLES

After the alarm is triggered, but before another alarm cycle starts, there is a
5" interval during which there will be no reaction to alarm events. The LED
will be ON steady. Normal flashing will resume at the end of the neutral time.
5.8

4.8 - ALARM DISARMING

The alarm system can be disarmed by pressing remote control button 1
by touching the electronic key to its receptacle. Disarming is confirmed by 3
flashes of the turn indicators.
If an alarm event has occurred while the system was armed, it will be
signaled by 5 flashes of the turn indicators.

4.9 - ALARM MEMORY

Five flashes of the turn indicators, when iginition is turned ON, will indicate an
alarm event has ocurred while you were away from your vehicle. The last
cause of alarm can be identified by observing the status LED and counting
the number of flashes.
The flashing sequence will be repeated 5 times. To interrupt, turn ignition key "OFF".
LED SIGNAL
Volumetric sensor
Door/boot switches
Bonnet switch/perimeter
Absorption sensor
External magnetic contact
LED OFF (2 seconds)
WIRE TAMPER will not be signaled by the alarm memory
because managed by the external self-powered siren.
OR
ALARM
ALARM CAUSE
CYCLES
5
5
5
sensors
5
Ignition attempt
No limitations
5
LED ON (400ms)