Gemini  GEM-P1664 Installation Instructions Manual
Gemini  GEM-P1664 Installation Instructions Manual

Gemini GEM-P1664 Installation Instructions Manual

Control panel/communicator
Hide thumbs Also See for Gemini GEM-P1664:

Advertisement

Publicly traded on NASDAQ
Symbol: NSSC
HARDWIRE
CONTROL PANEL/COMMUNICATOR
For use with "Classic" keypads (GEM-RP1CAe2, GEM-RP2ASe2, GEM-RP3DGTL and GEM-RP4RFC/GEM-RP4C)
and with "K Series" keypads (GEM-K1CA, GEM-K2AS, GEM-K3DGTL, and GEM-K4RF/GEM-K4)
G E M I N I
SYSTEM READY
09/01/05
R
1
B
4
C
7
C O M P UT E R I ZE D S E C U R I T Y S Y S T E M
"K Series" GEM-K1CA
GEMINI
32
A
1 2
R
B
4
C
7 8 9 0
COMPUTERIZED SECURITY SYSTEM
"K Series" GEM-K3DGTL
© NAPCO 2006
R
G E M - P 1 6 6 4
12:00 AM
NEXT/YES
U
P
2
3
PRIOR/NO
Q
5
6
AREA
8
9 0
G
SYSTEM ARMED
ENT A1
01/01/97
12:00AM
INTERIOR
BYPASS
FIRE/TBL
SYS TBL
CHIME
NEXT/YES
3
E
D
PRIOR/NO
5 6
F
AREA
G
R
INSTALLATION
INSTRUCTIONS
WIRELESS
GEMINI
SYSTEM ARMED
READY
01/01/97
12:00AM
READY
AC ON
AC ON
A
1 2
3
R
D
B
4
5 6
C
7 8 9 0
COMPUTERIZED SECURITY SYSTEM
"K Series" GEM-K2AS
"K Series" GEM-K4RF
NEXT/YES
E
PRIOR/NO
F
AREA
G
R
WI1424A 1/06

Advertisement

Table of Contents
loading

Summary of Contents for Gemini Gemini GEM-P1664

  • Page 1 "K Series" GEM-K1CA "K Series" GEM-K2AS GEMINI SYSTEM ARMED ENT A1 01/01/97 12:00AM INTERIOR BYPASS FIRE/TBL SYS TBL CHIME NEXT/YES PRIOR/NO AREA 7 8 9 0 COMPUTERIZED SECURITY SYSTEM "K Series" GEM-K3DGTL "K Series" GEM-K4RF © NAPCO 2006 WI1424A 1/06...
  • Page 2: Important Notice

    Page 6: Specifications: Current ratings updated. Page 59: Wiring Diagram updated. Refer to accompanying GEM-P1664 Programming Instructions (WI1422 and WI1423) for programming information. NAPCO Security Systems, Inc. 333 Bayview Avenue, Amityville, New York 11701 For Sales and Repairs, call toll free: (800) 645-9445 For direct line to Technical Service, call toll free: (800) 645-9440 Internet: http://www.napcosecurity.com...
  • Page 3: Table Of Contents

    Zone Expansion Device Compatibility ..... 15 4-Wire Smoke Detectors ......... 15 2-Wire Smoke Detectors ......... 15 Telephone Lines ............16 KEYPAD CONFIGURATION MODE ....... 17 Keypad Installation ..........17 Configuring the Keypads ......... 17 NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 4: Introduction

    Conventional LEDs and a sounder are also provided for annunciation. Data may be quickly and easily downloaded to the control panel using a PC-compatible computer with Napco's PCD- Windows Quickloader software and PCI2000 computer interface. Or, the panel may be programmed using the keypad in its secondary mode of operation.
  • Page 5: Important Note

    False Alarm Reduction Control Panel-01 Standard (SIA FAR CP-01). IMPORTANT NOTE This manual supports the keypad programming of the GEM-P1664 control panel with the NAPCO "classic" GEM- RP1CAe2, GEM-RP2ASe2, and GEM-RP3DGTL keypads as well as the GEM-K1CA, GEM-K2AS, and GEM-K3DGTL "K Series"...
  • Page 6: Specifications

    Maximum Number of Keypads: 7 Maximum Wiring Length for each run (#22AWG): 1000' divided by total number of keypads and EZMs on run Keypad Dimensions: 4” x 5” x 1” (HWD); 11.1cm x 14.9cm x 2.7cm (HWD) NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 7: Ordering Information

    Napco Group Europe Ltd. GEM-TEMP64: GEM-P1664 indoor/outdoor program- Libra Wireless Transmitters and Receivers for connec- mable temperature sensor* tion to Napco Intruder Control Panels (Operates on RM3008: Relay Module (in enclosure) 433MHz, European Approved Frequency) M278: Line-Reversal Module PS3002: Power-Supply Module, 13.2Vdc, 1.9A* WI925: LIBRA-RECVXP-433 Wireless 8 Zone Receiver EOL2.2K: End-of-Line Resistor Assy., 2.2k Ohm...
  • Page 8: Summary Of Ul Requirements

    Keypad Expansion (EZM) Zones are not to be used as fire zones Keypad Auxiliary is not to be selected The GEM-K Series Keypads must have the indicators printed on the face label (Fire, Police and Auxiliary) covered by a supplied label if not in use. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 9: Installation

    Then, using hardware suitable for the mounting surface, add one or two screws at the right side of the keypad case directly into the wall to ensure a secure installation. Note: Do not overtighten the screws! Uneven walls may cause the keypad case to distort. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 10: Wiring

    The sounding device must be placed such that the bell test can be heard by all partitions. Note: NFPA 74 (Household Fire Warning Equipment) requires that a fire alarm audible device be installed indoors. The User Program Code is not to be given to anyone except the authority responsible for all partitions. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 11: Testing The System

    Note that if the signal strength is less than 3, the keypad will not beep and the strength will not be displayed. Except in the Fault-Find Mode, signal strengths less than 3 will be entered into the system log. Upon zone restore, the keypad will beep once. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 12: Wiring Connections

    Instructions). Connect the device controlled by the programmable output between terminal 5 (+) and the PGM output (-), either terminal 7 or 8. As an example, the connection to the RB1000 Relay Module is shown. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 13: Remote Bus

    EARTH GROUND screw to the cabinet. NOTE: Grounding connections should avoid bends in the grounding wire whenever possible. NOTE: Do not use a gas pipe, plastic pipe or AC ground connections. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 14: Zone Configuration Styles

    WARNING: Assigning a fire zone or keyswitch zones to a zone doubled will disable the respective complimentary zone. For example, if zone 8 is assigned as a fire zone, it will disable zone 16. If zone 3 is assigned as a fire zone, it will disable zone 11. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 15: Zone Expansion Device Compatibility

    (15 & 16) are disabled when 2-wire smoke detectors are connected to zones 7 & 8. If Fire Alarm Verification is desired to reset the smoke detectors, select this option for the desired fire zone (zone 7 or 8). NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 16: Telephone Lines

    When communicating to central station and during downloading, the control panel seizes the telephone lines from the house phones, rendering them inoperative during communication. Upon completion of central station communication, the telephone line is restored to the house phones. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 17: Keypad Configuration Mode

    A valid number will be acknowledged by a short beep; an invalid number will be rejected by a long beep. 2. Press the button to continue or press the button to exit. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 18 (the display will loop back through 01 OUT OF selections, for changes) or press the button to exit the Keypad Configuration Mode (display will read “ SYSTEM ”). Then replace Jumper JP1 across Pins 1–2 (top two). NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 19 Cut Jumper B to disable LCD backlighting. DISABLE SOUNDER Cut Jumper to disable the sounder. (Do not disable in UL applications). NAPCO Security Systems, Inc. 333 Bayview Avenue, Amityville, New York 11701 For Sales and Repairs, call toll free: (800) 645-9445 For direct line to Technical Service, call toll free: (800) 645-9440 Internet: http://www.napcosecurity.com...
  • Page 20: Basic Operation

    ] to move cursor right, press [ ] to move cursor left. To advance to the next zone (or to any other zone), move the cursor to the displayed zone number (i.e., “01”) using NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 21: Arming And Disarming The System

    , then enter your user code and press . With the "K Series" keypads, enter your user code and press . Then press and hold until key- pad beeps Instant Arming will be automatically reset on disarming. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 22 4. To return the keypad to its “home” area, press the button, then the button. Note: If the “home” keypad has been changed to the alternate area and unused for more than 5 minutes, it will revert to the home area. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 23: Bypassing Zones

    DISPLAY ZN FAULTS Press the YES button to identify all unsecured zones (within the keypad's area) while disarmed. Press NEXT but- ton to scroll through the zones. Manually bypassed zones will be indicated when displaying status. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 24 Displays most recent system events. Line 1 displays event and date. Line 2 displays time and other pertinent in- formation, where necessary, depending upon event. To check previous system events, scroll back using the PRIOR button. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 25 Used on-site for remote downloading of a control-panel program from the PCD-Windows Quickloader Download soft- ware. Press the NEXT/YES button to initiate the data transfer. ENABLE DEALER MODE Refer to the chart on page 52. ENABLE USER MODE Refer to the chart on page 54. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 26: Keypad Messages

    Report Alarm, Report Codes, number. Subscriber ID Numbers, etc. must be programmed. FAULT FIND/RF SIGNAL POWER - Fault-find Mode activated. WIRELESS TROUBLE/04-NN SERVICE. Wireless transmitter supervisory failure. NN = transmitter number. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 27: Glossary

    Alarm Outputs (See Wiring Diagram for UL requirements); Alarm Output Duration The GEM-P1664 has three outputs: Alarm (Burg. & Fire), PGM1 and PGM2. The following table summarizes wiring for signaling an alarm in typical installations. See Time Selection for timeout durations. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 28 AUTO-ARM can be programmed to arm at a specific closing Time (such as: 17:00 representing 5:00 pm), for a notification length of time (such as: 00:02 representing 2 minutes), and a FAIL-TO-CLOSE has been enabled for a specific day of the week and area, and NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 29 Cancel; Cancel Code; Cancel Report to Telco 3; Cancel Window Duration (Report Cancel Window) CANCEL is the preventing of a report from being sent by entering a user disarm code. If the area is disarmed during Entry Delay or NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 30 Arming Code in Area 1, and after powering up, the installer is required to enter Program Mode using the Dealer Program Default Code of "456789". Press to exit the EZ Program menu. Access Location Cold Start, then press the button. Data Format NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 31 Day Zone condition will cause the alarm outputs programmed for that zone (sirens, relays) to activate. If Day Zone Trouble on Open is programmed, a zone configured as a 24 hour zone reports an alarm on short and a Day Zone trouble NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 32 Easy Bypass, recommended for residential applications, is selected by programming Disable Code Entry for Easy Bypass; this will permit bypassing/unbypassing zones without the need of entering a code. Do not program this feature in high- NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 33 E19 - Lug E19 is the Listen in Lug. It is an input and when it is forced low the panel will silence the keypad sounder and bell outputs so that the Veri-phone can listen to activity at the residence. See Veri-Phone (WI783): Silence All Outputs During Audio Session. Use Napco Part No. WL1 for field wiring. Easy Exit (Not evaluated by UL) While armed in the Interior Mode, Easy Exit can be initiated by pressing .
  • Page 34 However, if a device in the Exit/Entry Follower Zone detects a violation when the exit/entry door has not first been entered, there will be no entry delay and the Exit/Entry Follower NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 35 A printer can be made to print all logged operations directly from the panel, when programmed for "Enable GEM-PRINT Module" and a separate Gem-Print Module is added to the panel. Include Selective Bypass In Conditional Closing/Status See Closing Report. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 36 Report Test Timer on Telco1 or Telco 3 must be programmed. Keypad Jumpers (GEM-RP1CAe2 / GEM-K1CA) Refer to label LA1374 on the circuit board fishpaper for jumper locations and a summary of settings. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 37 The dynamic test may be initiated manually by pressing the button, or it will be initiated automatically, every four hours, by the panel. In wireless installations, when displaying RF transmitter status, a "LoBatt" indication denotes a low-battery condition at the transmitter. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 38 Select "Pre-Dial Delay" by programming one "D" for each 4-second delay required immediately before the telephone number. In UL NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 39 RM3008 (self-contained) or the RB3008 (to be mounted inside housing). The GEM-OUT8 is similar to the RM3008 but has open collector active low outputs in place of relays. The GEM-OUT8 is designed for NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 40 EZ Bypass; this will permit bypassing/unbypassing zones without the need of entering a code (see EZ Bypass in Section 3). Do not program this feature in high-security applications. When one or more zones is bypassed, the BYPASSED reminder on the GEM- RP1CAe2 and GEM-K1CA keypads will display. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 41 Start with the left-most location. Sum Check See Data Format Suppress Bypass Icon When Armed Program to inhibit the LCD "BYPASS" display while armed. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 42 Celsius by enabling address 1668 option 2. When this Temperature Display Option is enabled, Zone 6 becomes the input for the “Napco Temperature Sensor” module and Zone 6 of the panel becomes inoperative; if Zone Doubling is selected, zones 6, 14 will be inoperative.
  • Page 43 Test Timer; Cancel Next Test Timer Report on Any Report The test timer schedule is programmed via the Easy Program Menu and using Napco's Quickloader Software. If "Test Timer" is programmed, an automatic test report will be transmitted to the central station on the scheduled day(s) at the scheduled time. To report test timer, select Report Test Time to Telco 1 or 3 and program a report code.
  • Page 44 Address 2062 accepts three decimal digits which are multiplied by 10 milli-seconds to get a new value that replaces the default value of 750ms. If the location is set to 000 the system will default to 750ms internally. The maximum value is 255. If a value above NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 45 Note: Do not program a Day Zone as a 24-Hour Zone. 24 Hour Day Zone Trouble--Normally used for a hidden N/C panic button that when pressed, trips an alarm. Switch open = alarm. Short or cut in the loop = trouble. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 46: Standby-Battery Calculation Worksheet

    (Alarm Time) (Box 3) Alarm current drawn in alarm. Alarm Time in Hours. Example: For a 15 minute alarm timeout, Alarm Time = 15/60 = 0.25. MINIMUM REQUIRED BATTERY CAPACITY = BOX 2 + BOX NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 47: Wiring Legend

    Should removal of the circuit board be necessary, use this wiring legend to relocate wire leads to their proper terminals. Enter wire identification number or color code in WIRE NUMBER column and enter wire function in DESCRIPTION column (optional). TERMINAL WIRE NO. DESCRIPTION NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 48: Keypad Programming Modes

    ACTIVATE DIALER TEST TO ARM IN 1-4HRS/PRESS 1-4 Always TO DELAY AUTO ARM/PRESS 1-4 If Auto Arm? ACTIVATE PROGRAM Always ACTIVATE DOWNLOAD Always Repeat N/A means Not Available. Press button to Exit at any time NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 49: Dealer Mode

    TO ARM IN 1-4HRS/PRESS 1-4 Always If Auto Arm? TO DELAY AUTO ARM/PRESS 1-4 Always ACTIVATE PROGRAM Always ACTIVATE DOWNLOAD Repeat EASY MENU MODE (See Next Page) Press button to Exit at any time N/A means Not Available. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 50: Easy Menu Mode

    See WI for Info Rcvr Format press . Press again to silence any Enter user code system troubles. XMIT#+CS P KF A XMIT#+CS OP 01 (ZONE DESCRIPTIONS) ** Enter Date** Enter Time ** Dealer Code Test Timer Repeat NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 51: User Mode

    ZONE DESCRIPTIONS * DATE * TIME * (01-64) * Not avialable in GEM-RP2AS/RP2ASe/RP2ASe2 keypads. To enter Date and Time, GEM-RP1CAe2 keypad (version 6 or greater) must be used. Press button to Exit at any time NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 52: Keypad Configuration Mode

    (“01 OUT OF SYSTEM”) Return Jumper JP1 * from Pins 2-3 to Pins 1-2 (“SYSTEM READY”) * JP1 is located at the top center of the circuit board. ** Not available in the GEM-P1664. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 53: Quick Reference Chart

    Duress Feature. The existing programmable option "Enable Global Ambush" must not be enabled in CP-01 installations. It Pre-existing feature is not enabled in the factory program and is not enabled when Enable CP-01 Feature is selected in the Easy Program Menu. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 54 **Illustrates the LCD display for the GEM-RP2ASe2/GEM-K2AS, and GEM-RP3DGTL/GEM-K3DGTL keypads. Although the data is the same, the GEM- RP3DGTL/GEM-K3DGTL keypads will display the data differently--the address location number scrolls, then disappears briefly; the keypad will then dis- play the data entry locations. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 55: Factory Default Description

    The reporting format is selectable in the Easy Program Mode. Touch Tone with Rotary Back-up is enabled. Exit Delay = 60 seconds. Entry Delay 1 and 2 are both 30 seconds. AC Fail Report Delay is 60 minutes. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 56 After exiting the Easy Program Mode, the installer could complete the installation. Subsequent entering of Dealer Program Mode allows only a subset of the Easy Program menu that prevents the existing program from being deleted, but allows the system to be expanded. NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 57: Fcc Statement

    NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 58 Page 58 WI1424A 1/06 NOTES NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 59: Gem-P1664 Wiring Diagram

    WI1424A 1/06 Page 59 GEM-P1664 WIRING DIAGRAM 550mA 550mA MODEL-DELAY-SEC NAPCO Security Systems GEM-P1664 Installation Instructions...
  • Page 60: Limited Warranty

    NAPCO will, within said period, at its option, repair or replace any In no event shall NAPCO be liable for an amount in product failing to operate correctly without charge to the excess of NAPCO's original selling price of the product, original purchaser or user.

Table of Contents