6.13
Gear units with cooling coil
•
Before connecting the cooling coil the screw plugs must be removed from the connecting bushes.
•
Flush the cooling coil (in order to remove any contamination).
•
Connect the coolingwater in and outflow pipes (for exact position of the connections,
see dimensioned drawing).
Observe also item 5.10.2.
6.14
Gear unit with addon components
•
For the technical data to the addon components, as stated in item 6.15 to 6.20, refer to the
orderspecific list of equipment.
The electrical equipment for regulation and control must be wired in accordance with
the equipment suppliers' instructions.
For operation and maintenance the operating instructions provided specifically for
the order and the specifications in items 5.10.2 to 5.13 must be observed.
6.15
Gear units with addon air oilcooler
•
Wire the contamination indicator for switchover filter (for gear sizes $$ 13) and pressure monitor
electrically.
•
Wire the fan motor electrically.
Observe also item 5.10.3.
6.16
Gear units with addon water oilcooler
•
Before connecting the water oilcooler remove the sockets from the coolingwater connections.
•
Flush the water oilcooler (in order to remove any contamination).
•
Install the coolingwater in and outflow pipes (for flow direction and exact position of connections,
see dimensioned drawing).
Make sure when installing the piping that no forces, moments or vibrations act upon
the connections of the water oilcooler.
•
Wire the pressure monitor electrically (in case of gear units with corresponding equipment only).
Observe also item 5.10.4.
6.17
Gear unit with oiltemperature monitoring system
•
Wire the resistance thermometer with evaluating instrument (to be provided by customer) electrically.
6.18
Gear unit with oillevel monitoring
•
Wire the levellimit switch electrically.
6.19
Bearingmonitoring system
•
The bearing-monitoring device must be fitted by the customer.
6.20
Gear unit with speed transmitter
•
Wire the speed transmitter electrically.