3
2
1
H1.. / H2.. ≤ 12
Fig. 23: Air oilcooling system on gear units types H1.. and H2..
3
2
1
B2.. ≤ 12
Fig. 24: Air oilcooling system on gear units type B2..
1
Flange pump
2
Pressure monitor
3
Coarse filter
A detailed view of the gear unit can be obtained from the drawings in the gearunit documentation.
When installing the gear unit with an addon air oilcooler, it must be ensured that the
air circulation is not obstructed.
The required minimum distance from adjacent components, walls, etc. is indicated in
the drawings in the unit documentation.
Depending on the application, the flange pump may have been replaced with a motor pump.
When operating and servicing the components of the oilsupply system, observe the
operating instructions of the components.
For technical data, refer to the data sheet and/or the list of equipment.
The cooling effect is considerably reduced if the cooler or the gear housing are dirty (see section 10,
"Maintenance and repair").
6
5
1
6
5
1
4
Double changeover filter
5
Air oilcooler
6
Temperaturecontrol valve
BA 5030 en 02/2013
37 / 96
2
4
H1.. / H2.. ≥ 13
2
4
B2.. ≥ 13
6
5
6
5