6.12
Fitting supports for gearunit swing base
6.12.1 Attaching the support
The support for the gearunit swing base must be mounted free of stress.
2
4
Fig. 55: Support for gearunit swing bases
1
Gear unit
2
Motor
3
Gearunit swing base
For realising the foundation for fastening the torque arm, see item 6.3.1 (Foundation).
6.13
Gear units with cooling coil
Before connecting the cooling coil the screw plugs must be removed from the connecting bushes.
Flush the cooling coil (in order to remove any contamination).
Connect the coolingwater in and outflow pipes (for exact position of the connections, see
dimensioned drawing).
Observe also item 5.10.2.
6.14
Gear unit with addon components
For the technical data to the addon components, as stated in item 6.15 to 6.22, refer to the
orderspecific list of equipment.
The electrical equipment for regulation and control must be wired in accordance with
the equipment suppliers' instructions.
For operation and maintenance the operating instructions provided specifically for
the order and the specifications in item 5.10.3 to 5.17.4 must be observed.
6.15
Gear units with air oilcooler
Wire the contamination indicator for switchover filter (for gearunit sizes
electrically.
Connect the fan motor electrically.
1
2
5
3
4
Torque arm
5
Support block
BA 5033 EN 03/2011
69 / 96
1
3
13) and pressure monitor