Installation

Connect Power

All electrical wiring must be done by a qualified elec-
trician and comply with all local codes and regula-
tions.
Letters in parenthesis are used in this section for refer-
ence to callouts in the Component Identification sec-
tion starting on page 7.
1. Cut power cord wires to the following lengths:
Ground wire - 6.5 inches (16.5 cm)
Power wires - 3.0 inches (7.6 cm)
Add ferrules as necessary. See Figure 3.
F
. 3: Power Cord
IG
2. Remove the four screws to separate the junction
box cover and disconnect switch (J) from the junc-
tion box (F) on the electric driver.
F
J
F
. 4: Remove Junction Box Cover
IG
10
NOTE: Inside the junction box, power wires to the driver
are connected to terminals 3L2 and 5L3 on the discon-
nect block. Refer to Figure 5 for the terminal locations.
Power to
Driver
Disconnect
Block
F
. 5: Terminal Connections
IG
3. Insert the power cord through the cord grip and into
the junction box.
Cord Grip
F
. 6: Connect Power
IG
4. Refer to Figure 5 and connect the wires from the
power cord into terminals 4T2 and 6T3. Each wire
can be connected to either terminal.
5. Attach the ground wire to one of the two ground ter-
minals inside the junction box as shown in Figure 6.
Incoming
Power
For clarity, power wires to
the driver are not shown
3A6586A